Snmp如下含义咨询,没有找到5对应的含义
;hh3cEntityExtErrorStatus(1.3.6.1.4.1.25506.2.6.1.1.1.1.19.9874)=5
从mib browser看了下这个节点的内容,error status = 5表示光功率临近阈值。这个信息在mib手册没找到,不过网管在解析mib库时应该能获取到这个信息,估计现网网管没做完整的解析。
,这个mib要导入到网网管软件上,网管软件自己就能识别出来,
目前没有文档说明这个参数的意义,需要网管设备来识别,然后在网管设备上查看
https://www.h3c.com/cn/d_201806/1089291_473262_0.htm
Name: hh3cEntityExtErrorStatus
Type: OBJECT-TYPE
OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.19
Full path: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cCommon(2).hh3cEntityExtend(6).hh3cEntityExtObjects(1).hh3cEntityExtState(1).hh3cEntityExtStateTable(1).hh3cEntityExtStateEntry(1).hh3cEntityExtErrorStatus(19)
Module: HH3C-ENTITY-EXT-MIB
Parent: hh3cEntityExtStateEntry
Prev sibling: hh3cEntityExtMacAddress
Next sibling: hh3cEntityExtCpuMaxUsage
Numerical syntax: Integer (32 bit)
Base syntax: INTEGER
Composed syntax: INTEGER
Status: current
Max access: read-only
Value list: 1: notSupported(1)
2: normal(2)
3: postFailure(3)
4: entityAbsent(4)
5: nearThresholdError(5)//
6: poeError(11)
7: stackError(21)
8: stackPortBlocked(22)
9: stackPortFailed(23)
10: sfpRecvError(31)
11: sfpSendError(32)
12: sfpBothError(33)
13: fanError(41)
14: psuError(51)
15: rpsError(61)
16: moduleFaulty(71)
17: sensorError(81)
18: hardwareFaulty(91)
Description: Indicate the error state of this entity object. Now it only
supports Port, general power supply, RPS power supply and
board/Subcard. It may have one of these values.
The following four values can be used for all kinds of entities.
notSupported(1) means this entity cannot support this function.
normal(2) means the statement of this entity is normal. for ports,
it doesn't differentiate 10M/s, 100M/s, 1000M/s, duplex and
half-duplex. For fan, power supply and board-Subcard, it means
their states are normal.
postFailure(3) means the entity fails to POST.
entityAbsent(4) means the entity is absent now.
nearThresholdError(5) means the transceiver power reaches 3dB to the threshold.
The following values is depended on the entity.
For Port entities, it may have the following values. If its POST
is failure,
then the value of the instance will be postFailure(3), otherwise
the value will be normal(2).
If enable power supply over Ethernet on this port is failure,
the value of this instance will be poeError(11), otherwise it will
be normal(2).
For stack port, if it connects to another stack port normally, and
these two units merge into one stack, then the value of this
instance will be normal(2).
If something wrong occurs and the unit cannot merge into stack,
the value of this instance will be stackPortFailed(23). If the
stack port forms resilient daisy chain with another stack port
on the other unit, the value of this instance will be
stackPortBlocked(22).
For SFP ports, if it fail to receive, the value of this instance
will be sfpRecvError(31), if it fail to send, the value is
sfpSendError(32), if it fail to send and receive, the value is
sfpBothError(33), otherwise it will be normal(2).
fanError(41) means that the fan stops working.
psuError(51) means that the Power Supply Unit is in the state of
fault.
rpsError(61) means the RPS is in the state of fault.
moduleFaulty(71) means the Module is in the state of fault.
sensorError(81) means the sensor is in the state of fault.
hardwareFaulty(91) means the hardware of specified entity is in the state of fault.
NMS must be compatible with the states which may be added
in the future.