H3C S6800系列交换机FCoE+FC网络部署案例

2020-09-01发表
  • 4收藏
河子 八段

描述

服务器(Server)与存储(Storage)通过FC HBA网卡连接S6800的SW1、2交换机,服务器需要访问存储设备,但是SW1与SW2交换机之间互联的接口没有多余FC模块,仅能使用普通的以太网光模块进行互联。因此需要SW1、SW2设备部署FCoE+FC方式实现Server与Storage之间互访。

具体SW1、SW2部署方式,请参考如下配置:


SW1交换机关键配置如下:

#
 fcoe-mode fcf
#
vsan 100
 domain-id 1 static
 zone mode enhanced
 zone default-zone permit
 zone name S1-1
  pairwise-zoning enable
  member pwwn 20:11:00:02:ac:00:a1:f9 target   
//存储FC网卡WWN
  member pwwn 51:40:2e:c0:00:55:cc:20 initiator //服务器FC网卡WWN
 zoneset name S-1
  member S1-1
 zoneset activate name S-1

 delete zone database all 
#
vlan 100       
 fcoe enable vsan 100

#
interface Fc1/2/1
 fc mode f
 port access vsan 100
 qos trust dot1p

#
interface Vfc120
 fc mode e
 port trunk vsan 100
 bind interface Ten-GigabitEthernet1/0/1

#
interface Ten-GigabitEthernet1/0/1
 port link-mode bridge
 port link-type trunk
 port trunk permit vlan 1 100
 priority-flow-control auto 
 priority-flow-control no-drop dot1p 3 
 qos trust dot1p

#

SW2交换机关键配置如下:

#
 fcoe-mode fcf
#
vsan 100
 domain-id 2 preferred
 zone mode enhanced
 zone default-zone permit
 zone name S1-1
  pairwise-zoning enable
  member pwwn 20:11:00:02:ac:00:a1:f9 target   
//存储FC网卡WWN
  member pwwn 51:40:2e:c0:00:55:cc:20 initiator //服务器FC网卡WWN
 zoneset name S-1
  member S1-1
 zoneset activate name S-1

 delete zone database all 
#
vlan 100       
 fcoe enable vsan 100

#
interface Fc1/2/1
 fc mode f
 port access vsan 100
 qos trust dot1p

#
interface Vfc120
 fc mode e
 port trunk vsan 100
 bind interface Ten-GigabitEthernet1/0/1

#
interface Ten-GigabitEthernet1/0/1
 port link-mode bridge
 port link-type trunk
 port trunk permit vlan 1 100
 priority-flow-control auto 
 priority-flow-control no-drop dot1p 3 
 qos trust dot1p

#

通过上述方式部署后,在SW1、SW2上分别查看名称服务数据库信息,均能够看到Server与Storage的PWWN,可实现服务器与存储设备之间互访。

[SW1]dis fc name-service database 
VSAN: 100
  FCID     Type               PWWN(vendor)                      FC4-type:feature
  0x010000 0x01(N)            20:11:00:02:ac:00:a1:f9           SCSI-FCP:Target
  0x010001 0x01(N)            51:40:2e:c0:00:55:cc:20           SCSI-FCP:Initiator
  ......

[SW2]dis fc name-service database 
VSAN: 100
  FCID     Type               PWWN(vendor)                      FC4-type:feature
  0x010000 0x01(N)            20:11:00:02:ac:00:a1:f9           SCSI-FCP:Target
  0x010001 0x01(N)            51:40:2e:c0:00:55:cc:20           SCSI-FCP:Initiator
  ......

注意,虽然SW2上vsan 100中配置了domain-id 2 preferred,但是其存储(PWWN:20:11:00:02:ac:00:a1:f9)的domain-id为1(FCID 0x010000)。为什么存储FC网卡的domian不采用SW2的domain-id,而是采用SW1的domain-id 1呢?这是由于一个VSAN内选择了SW1为主交换机,该VSAN内的存储或服务器均采用主交换机的domain-id。

选择主交换机判断依据为:

1、FCF优选级数值越小越优先

2、交换机WWN号越小越优先

对于SW1和SW2其优先级均采用默认的优先级Priority 128,但是SW1的WWN小于SW2的WWN,因此VSAN100选择SW1作为主交换机。

[SW1]display fc domain vsan 100
     Running time information:
     State: Stable
     Switch WWN:  10:00:0c:da:41:98:52:27 //SW1的WWN号小于SW2的WWN号,因此做为VSAN100主交换机
     Fabric name: 10:00:0c:da:41:98:52:27
     Priority: 128      
 

[SW2]display fc domain vsan 100
     Running time information:
     State: Stable
     Switch WWN:  10:00:0c:da:41:9d:fe:35
     Fabric name: 10:00:0c:da:41:9d:fe:35
     Priority: 128 

提出建议

    +

亲~登录后才可以操作哦!

确定

你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作