某局点SecPath M9000(V7) nsqm1fwefgA0 CPU 1 Fault

  • 1关注
  • 1收藏 1405浏览
粉丝:1人 关注:0人

组网及说明

问题描述

SecPath M9000(V7) nsqm1fwefgA0 CPU 1 Fault


================================================

  ===============display device verbose=============== 

Slot No. Brd Type         Brd Status   Subslot Sft Ver                Patch Ver

0       NSQM1FWEFGA0     Normal       0       M9016-V-9153P3002      None     

         CPU 1            Fault        0       NONE                  

 1       NSQM1FWEFGA0     Normal       0       M9016-V-9153P3002      None     

         CPU 1            Fault        0       NONE                  

 2       NONE             Absent       0       NONE                   None     

 3       NSQM1CGQ4TG24SHA0Normal       0       M9016-V-9153P3002      None     

 4       NSQM1SUPD0       Master       0       M9016-V-9153P3002      None     

 5       NSQM1SUPD0       Standby      0       M9016-V-9153P3002      None     

 6       NSQM1CGQ4TG24SHA0Normal       0       M9016-V-9153P3002      None     

 7       NONE             Absent       0       NONE                   None     

 8       NONE             Absent       0       NONE                   None     

 9       NONE             Absent       0       NONE                   None     

 10      NSQM1FAB08E0     Normal       0       M9016-V-9153P3002      None     

 11      NSQM1FAB08E0     Normal       0       M9016-V-9153P3002      None     

 12      NSQM1FAB08E0     Normal       0       M9016-V-9153P3002      None     

 13      NSQM1FAB08E0     Normal       0       M9016-V-9153P3002      None     

过程分析

现场误删除业务板版本,主控console设备显示CPU fault

================================================

  ===============display device verbose=============== 

Slot No. Brd Type         Brd Status   Subslot Sft Ver                Patch Ver

0       NSQM1FWEFGA0     Normal       0       M9016-V-9153P3002      None     

         CPU 1            Fault        0       NONE                  

 1       NSQM1FWEFGA0     Normal       0       M9016-V-9153P3002      None     

         CPU 1            Fault        0       NONE                  

 2       NONE             Absent       0       NONE                   None     

 3       NSQM1CGQ4TG24SHA0Normal       0       M9016-V-9153P3002      None     

 4       NSQM1SUPD0       Master       0       M9016-V-9153P3002      None     

 5       NSQM1SUPD0       Standby      0       M9016-V-9153P3002      None     

 6       NSQM1CGQ4TG24SHA0Normal       0       M9016-V-9153P3002      None     

 7       NONE             Absent       0       NONE                   None     

 8       NONE             Absent       0       NONE                   None     

 9       NONE             Absent       0       NONE                   None     

 10      NSQM1FAB08E0     Normal       0       M9016-V-9153P3002      None     

 11      NSQM1FAB08E0     Normal       0       M9016-V-9153P3002      None     

 12      NSQM1FAB08E0     Normal       0       M9016-V-9153P3002      None     

 13      NSQM1FAB08E0     Normal       0       M9016-V-9153P3002      None    

 

Boot-loader没有0 1槽位信息

  ===============boot-loader infomation=============== 

Software images on slot 4:

Current software images:

  flash:/M9000-CMW710-BOOT-R9153P3002.bin

  flash:/M9000-CMW710-SYSTEM-R9153P3002.bin

Main startup software images:

  flash:/M9000-CMW710-BOOT-R9153P3002.bin

  flash:/M9000-CMW710-SYSTEM-R9153P3002.bin

Backup startup software images:

  None

Software images on slot 5:

Current software images:

  flash:/M9000-CMW710-BOOT-R9153P3002.bin

  flash:/M9000-CMW710-SYSTEM-R9153P3002.bin

Main startup software images:

  flash:/M9000-CMW710-BOOT-R9153P3002.bin

  flash:/M9000-CMW710-SYSTEM-R9153P3002.bin

Backup startup software images:

  None

 

 

SecBladeV指型号为:NSQM1FWEFGA0的业务单板。


不支持主控升级

1.6  升级CPLDFPGA等固件

1. 功能简介

设备上某些固件(包括CPLDFPGACPU3G Modem模块等)运行的不是Comware系统,这样的固件需要使用特定的软件单独升级。

2. 硬件适配关系

本特性的支持情况与设备型号有关,请以设备的实际情况为准。

设备型号

业务板类型

说明

M9006

M9010

M9014

FW业务板Blade III

不支持

FW业务板Blade IV

不支持

FW业务板Blade V

不支持

NAT业务板

不支持

ADE业务板

不支持

AFC业务板

不支持

M9010-GM

加密业务板

不支持

M9016-V

FW业务板Blade V

不支持

M9008-S

M9012-S

FW业务板

不支持

ADE业务板

不支持

IPS业务板

不支持

视频网关业务板

不支持

AFC业务板

不支持

M9008-S-6GW

IPv6业务板

不支持

M9000-AI-E8

M9000-AI-E16

FW业务板

支持

直接在主控加载对应版本选不到slot01

 

查看版本说明书,进入console配置


直接console进去输出乱码



解决方法

 

从主控进入boot界面重新升级加载。

该案例对您是否有帮助:

您的评价:1

若您有关于案例的建议,请反馈:

作者在2022-04-06对此案例进行了修订
0 个评论

该案例暂时没有网友评论

编辑评论

举报

×

侵犯我的权益 >
对根叔知了社区有害的内容 >
辱骂、歧视、挑衅等(不友善)

侵犯我的权益

×

泄露了我的隐私 >
侵犯了我企业的权益 >
抄袭了我的内容 >
诽谤我 >
辱骂、歧视、挑衅等(不友善)
骚扰我

泄露了我的隐私

×

您好,当您发现根叔知了上有泄漏您隐私的内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到zhiliao@h3c.com 邮箱,我们会尽快处理。
  • 1. 您认为哪些内容泄露了您的隐私?(请在邮件中列出您举报的内容、链接地址,并给出简短的说明)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)

侵犯了我企业的权益

×

您好,当您发现根叔知了上有关于您企业的造谣与诽谤、商业侵权等内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到 zhiliao@h3c.com 邮箱,我们会在审核后尽快给您答复。
  • 1. 您举报的内容是什么?(请在邮件中列出您举报的内容和链接地址)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)
  • 3. 是哪家企业?(营业执照,单位登记证明等证件)
  • 4. 您与该企业的关系是?(您是企业法人或被授权人,需提供企业委托授权书)
我们认为知名企业应该坦然接受公众讨论,对于答案中不准确的部分,我们欢迎您以正式或非正式身份在根叔知了上进行澄清。

抄袭了我的内容

×

原文链接或出处

诽谤我

×

您好,当您发现根叔知了上有诽谤您的内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到zhiliao@h3c.com 邮箱,我们会尽快处理。
  • 1. 您举报的内容以及侵犯了您什么权益?(请在邮件中列出您举报的内容、链接地址,并给出简短的说明)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)
我们认为知名企业应该坦然接受公众讨论,对于答案中不准确的部分,我们欢迎您以正式或非正式身份在根叔知了上进行澄清。

对根叔知了社区有害的内容

×

垃圾广告信息
色情、暴力、血腥等违反法律法规的内容
政治敏感
不规范转载 >
辱骂、歧视、挑衅等(不友善)
骚扰我
诱导投票

不规范转载

×

举报说明

提出建议

    +

亲~登录后才可以操作哦!

确定

亲~检测到您登陆的账号未在http://hclhub.h3c.com进行注册

注册后可访问此模块

跳转hclhub

你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作