不涉及
升级后交换网板起不来,
%Apr 14 18:50:44:090 2022 H3C DEV/4/BOARD_LOADING: -MDC=1; Board in slot 10 is loading software images.
%Apr 14 18:50:44:130 2022 H3C DEV/4/BOARD_LOADING: -MDC=1; Board in slot 12 is loading software images.
%Apr 14 18:50:47:242 2022 H3C DEV/5/LOAD_FINISHED: -MDC=1; Board in slot 10 has finished loading software images.
%Apr 14 18:50:47:242 2022 H3C DEV/5/LOAD_FINISHED: -MDC=1; Board in slot 12 has finished loading software images.
%Apr 14 18:50:54:202 2022 H3C DEV/4/BOARD_LOADING: -MDC=1; Board in slot 11 is loading software images.
%Apr 14 18:50:54:207 2022 H3C DEV/4/BOARD_LOADING: -MDC=1; Board in slot 13 is loading software images.
%Apr 14 18:50:57:355 2022 H3C DEV/5/LOAD_FINISHED: -MDC=1; Board in slot 11 has finished loading software images.
%Apr 14 18:50:57:356 2022 H3C DEV/5/LOAD_FINISHED: -MDC=1; Board in slot 13 has finished loading software images.
%Apr 14 18:50:58:713 2022 H3C DEV/4/BOARD_LOADING: -MDC=1; Board in slot 12 is loading software images.
%Apr 14 18:50:58:713 2022 H3C DEV/4/BOARD_LOADING: -MDC=1; Board in slot 10 is loading software images.
Slot No. Brd Type Brd Status Software Version
10 NONE Fault NONE
11 NONE Fault NONE
12 NONE Fault NONE
13 NONE Fault NONE
现场从7951的版本升级到8260P22的版本,发现交换网板无法启动
查看加载文件:
Software images on slot 4:
Current software images:
cfa0:/SR8800R-CMW710-BOOT-R8260P22.bin //是R版本
cfa0:/SR8800R-CMW710-SYSTEM-R8260P22.bin
cfa0:/SR8800R-CMW710-DEVKIT-R8260P22.bin
cfa0:/SR8800-CMW710-SYSTEM-R8260P22H02.bin
现场设备为8808-X,R版本为8808H-X和8816-X使用, 这个版本下,升级后交换网板会起不来。
替换为对应版本。 目前高端路由器机框和版本不符提示报错的需求已经提交,后续版本合入。
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作