设备型号:S10506X
版本:R7596P09
现场两台S10506X堆叠,二层聚合口666对接对端S10506堆叠设备,终端网关在S10506上,报文在S10506X上做二层转发
现场发现,同网段终端互访不通,关闭两组堆叠核心设备上任一一条链路,只保留一条物理链路的情况下,可以正常互访。
Aggregate Interface: Bridge-Aggregation666
Creation Mode: Manual
Aggregation Mode: Dynamic
Loadsharing Type: Shar
Management VLANs: None
System ID: 0x8000, 305f-77e4-b800
Local:
Port Status Priority Index Oper-Key Flag
FGE1/4/0/6(R) S 32768 1 1 {ACDEF}
FGE2/4/0/6 S 32768 58 1 {ACDEF}
Remote: Actor Priority Index Oper-Key SystemID Flag
FGE1/4/0/6 32768 25 15 0x8000, d461-fe05-8e00 {ACDEF}
FGE2/4/0/6 32768 26 15 0x8000, d461-fe05-8e00 {ACDEF}
查看物理端口所在单板为EC单板:
===============display device verbose===============
Slot Type State Subslot Soft Ver Patch Ver
1/0 LSUM1TGS48SH0 Normal 0 S10500X-7596P09 None
1/1 LSUM1TGS48SH0 Normal 0 S10500X-7596P09 None
1/2 LSUM2GP48SA0 Normal 0 S10500X-7596P09 None
1/3 LSUM2GT48SA0 Normal 0 S10500X-7596P09 None
1/4 LSUM1QGS6EC0 Normal 0 S10500X-7596P09 None
查看聚合666端口底层信息发现底层没有对应端口:
[NW-CORE-probe]debug port trunk-global c 1 s 4 29a
TG=61
Agg=29a
[NW-CORE-probe]BCM C 1 slot 4 C 0 trunk/show
Device supports 1032 trunk groups:
1024 front panel trunks (0..1023), 256 ports/trunk
8 fabric trunks (1024..1031), 16 ports/trunk
trunk 61: (front panel, 1 ports)= dlf=any mc=any ipmc=any psc=portflow (0x9)
[NW-CORE-probe] bcm c 2 s 4 c 0 trunk/show
Device supports 1032 trunk groups:
1024 front panel trunks (0..1023), 256 ports/trunk
8 fabric trunks (1024..1031), 16 ports/trunk
trunk 61: (front panel, 1 ports)= dlf=any mc=any ipmc=any psc=portflow (0x9)
查看diagfile发现下发时由于资源不足返回失败:
%@625^Apr 26 20:12:41:158 2022 NW-CORE DRVPLAT/3/DrvDebug: -Chassis=2-Slot=4;
LINE:1722
MOD:TRUNK,TASK:laggd,-FILE id 0xd0000,SLOT:27--:
bcm_trunk_set returns error:No resources for operation, UnitID = 0
原因为EC单板作为堆叠板时,整框重启时堆叠板启动较快,在底层聚合表项下发时,某些资源未准备好,导致下发失败。
R7624P12已经解决这个问题,建议现网升级版本到R7624P12版本。