某单位刀片服务器,系统是
CentOS Linux release 7.1.1503 (Core)
操作系统下,使用IPMI -sensors 命令查看信息有时最后会有
ipmi_sensor_read: internal IPMI error
ipmi_sensor_read: internal IPMI error
具体操作如下:
//[root@cn13-d3-db-game-api08 ~]# ipmi-sensors
ID | Name | Type | Reading | Units | Event
0 | UID Light | OEM Reserved | N/A | N/A | 'OEM Event = 0001h'
1 | Sys. Health LED | OEM Reserved | N/A | N/A | N/A
2 | 01-Inlet Ambient | Temperature | 17.00 | C | 'OK'
3 | 02-CPU 1 | Temperature | 40.00 | C | 'OK'
4 | 03-CPU 2 | Temperature | 40.00 | C | 'OK'
5 | 04-P1 DIMM 1-4 | Temperature | 29.00 | C | 'OK'
6 | 05-P1 DIMM 5-8 | Temperature | N/A | C | N/A
7 | 06-P2 DIMM 1-4 | Temperature | 26.00 | C | 'OK'
8 | 07-P2 DIMM 5-8 | Temperature | N/A | C | N/A
9 | 08-P1 Mem Zone | Temperature | 34.00 | C | 'OK'
10 | 09-P1 Mem Zone | Temperature | 31.00 | C | 'OK'
11 | 10-P2 Mem Zone | Temperature | 29.00 | C | 'OK'
ipmi_sensor_read: internal IPMI error
后来发现所有的显示不正常都是通过oa 登录到刀片的ilo 中的机器全部有这个问题。 此问题OA与刀片ilo 之间通信,ilo 固件的问题导致。
登录到刀片的ilo 中,reset ilo 后问题解决.
1、 在刀片ilo 中看到的数据显示不准确或者是无法显示的问题,系统下看不到相关的信息, 可以考虑刀片ilo 和oa 之间的通信的问题
2、 刀片ilo 和OA的固件可以考虑一下
3、 reset ilo 或者重新插拔oa 让oa 和刀片ilo 之间重新建立连接恢复相应通信,抓取到相应的信息,之后更新ilo 固件。