现场两台交换机做的堆叠,想增加bfd配置,然后将1/0/47----2/0/47,2/0/47----2/0/48连接起来时发现接口不up,两个46口互连也不up。但是接口直接连接服务器就能up,服务器网卡是25G。
此交换机接口大部分是25G接口,接的25G光模块,接其他设备都能up。 目前发现互连的接口除了堆叠的100G口,都不能up。
WGE1/0/47 DOWN auto A A 1 pT:YHDC-5F1A03-YWZY-UNIS7
WGE1/0/48 DOWN auto A A 1 pT:YHDC-5F1A03-YWZY-UNIS7
WGE2/0/47 DOWN auto A A 1 pT:YHDC-5F1A03-YWZY-UNIS7
WGE2/0/48 DOWN auto A A 1 pT:YHDC-5F1A03-YWZY-UNIS7
查了光模块适配性没问题,光收发正常。
Twenty-FiveGigE1/0/47 transceiver diagnostic information:
Current diagnostic parameters:
Temp.(��C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
33 3.32 6.88 -0.62 -0.46
Alarm thresholds:
Temp.(��C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 80 3.63 20.00 4.40 4.40
Low -10 2.97 0.50 -12.30 -10.40
Twenty-FiveGigE1/0/48 transceiver diagnostic information:
Current diagnostic parameters:
Temp.(��C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
34 3.32 6.88 -0.65 -0.63
Alarm thresholds:
Temp.(��C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 80 3.63 20.00 4.40 4.40
Low -10 2.97 0.50 -12.30 -10.40
Twenty-FiveGigE2/0/47 transceiver diagnostic information:
Current diagnostic parameters:
Temp.(��C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
34 3.33 6.88 -0.42 -0.52
Alarm thresholds:
Temp.(��C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 80 3.63 20.00 4.40 4.40
Low -10 2.97 0.50 -12.30 -10.40
Twenty-FiveGigE2/0/48 transceiver diagnostic information:
Current diagnostic parameters:
Temp.(��C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
36 3.33 6.88 0.08 -0.61
Alarm thresholds:
Temp.(��C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 80 3.63 20.00 4.40 4.40
Low -10 2.97 0.50 -12.30 -10.40
查看端口的fec mode不一致:
Twenty-FiveGigE1/0/47
Current state: DOWN
Line protocol state: DOWN
IP packet frame type: Ethernet II, hardware address: hhhh-hhhh-hhhh
Description:
Bandwidth: 25000000 kbps
Loopback is not set
Media type is optical fiber, port hardware type is 25G_BASE_SR_SFP28
FEC mode: RS-528
Twenty-FiveGigE2/0/47
Current state: DOWN
Line protocol state: DOWN
IP packet frame type: Ethernet II, hardware address: hhhh-hhhh-hhhh
Description:
Bandwidth: 25000000 kbps
Loopback is not set
Media type is optical fiber, port hardware type is 25G_BASE_SR_SFP28
FEC mode: BASE-R
需要进端口视图手动修改下,“port fec mode base-r/rs-fec” ,两侧要一致,建议调整成rs-fec,然后再对接;
端口历史上插过电模块或者电缆都是有可能刷新过FEC模式、或者历史上有人调整过,都有可能引起FEC mode变化的;