%Apr 19 00:00:31:841 2022 QYDXD331-M-02-01 OPTMOD/4/MODULE_IN: -Slot=1; HundredGigE1/0/15: The transceiver is UNKNOWN_QSFP_PLUS.
单个接口无法识别光模块,替换测试确定为接口问题
HundredGigE1/0/15 transceiver information:
Reading or writing information from the transceiver failed.
HGE1/0/15 4 13 ce13 no no 0x138 25 down
查看locallog,I2C无法读取光模块,根据现场测试情况,判断是接口的I2C故障
Chassis00 slot01 2022/04/19 01:33:43:887251 [LINE:2312-TASK:bLK4-FUNC:drv_port_i2c_read_from_phy82381]:Read optical register error, unit is 4 port is 13.
Chassis00 slot01 2022/04/19 01:33:43:902431 [LINE:2321-TASK:bLK4-FUNC:drv_port_i2c_read_from_phy82381]:Read2 optical register error, unit is 4 port is 13.
Chassis00 slot01 2022/04/19 01:33:43:902466 [LINE:2406-TASK:bLK4-FUNC:DRV_PORT_MODULE_I2C_SREAD]:I2C_READ error! u=4 p=13 i2caddr=80 addr=86 byte=1
Chassis00 slot01 2022/04/19 01:33:43:999610 [LINE:4829-TASK:bLK4-FUNC:drv_port_I2c_module_state_set_for_QSFP]:I2C read error: ucRegVal = 0x0,ulRet = 1073807361
Chassis00 slot01 2022/04/19 01:33:43:999651 [LINE:4551-TASK:bLK4-FUNC:drv_port_txdisable_set]:drv_port_txdisable_set return error ret 0x40010001
更换识别