组网拓扑说明
S5560X-30F-EI 下连接入交换机的根端口状态一直在变化,大概40秒 左右1/0/27端口从discarding变化forwarding状态
%Aug 25 17:16:02:333 2018 BJ-TH04-S5110-AP-10.59.51.138 MSTP/6/MSTP_DISCARDING: Instance 0's port GigabitEthernet1/0/27 has been set to discarding state.
%Aug 25 17:16:02:334 2018 BJ-TH04-S5110-AP-10.59.51.138 MSTP/4/MSTP_LOOP_PROTECTION: Instance 0's LOOP-Protection port GigabitEthernet1/0/27 failed to receive configuration BPDUs.
%Aug 25 17:16:44:876 2018 BJ-TH04-S5110-AP-10.59.51.138 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/28 has been set to forwarding state.
%Aug
25 17:16:45:007 2018
BJ-TH04-S5110-AP-10.59.51.138 MSTP/6/MSTP_FORWARDING: Instance 0's port GigabitEthernet1/0/27 has been set to forwarding
state.
1、这种现象首先检查设备的配置,看看边缘端口,BPDU保护这些功能是否开启,检查设备确实是开启的,
2、向工程师确认是运行中突然出现,还是网络中新增加了其他的设备。
3、确认没有增加过新设备,是在网运行中突然出现的,然后检查设备诊断信息中的logbuffer信息
%Aug 25 17:16:02:331 2018 BJ-TH04-S5110-AP-10.59.51.138 MSTP/5/MSTP_BPDU_RECEIVE_EXPIRY: Instance 0's port GigabitEthernet1/0/27 received no BPDU within the rcvdInfoWhile interval. Information of the port aged out.
%Aug 25 17:16:02:333 2018 BJ-TH04-S5110-AP-10.59.51.138 MSTP/6/MSTP_DISCARDING: Instance 0's port GigabitEthernet1/0/27 has been set to discarding state.
%Aug 25 17:16:02:334 2018 BJ-TH04-S5110-AP-10.59.51.138 MSTP/4/MSTP_LOOP_PROTECTION: Instance 0's LOOP-Protection port GigabitEthernet1/0/27 failed to receive configuration BPDUs.
看到信息可能是因为是链路存在丢包导致bpdu超时,因为现场采用的光模块和光纤连接,确认是我司的之后让其更换光模块和光纤测试
4、更换过光纤和光模块之后,工程师后续反馈还是会存在同样的现象。
5、后续继续排查是设备上CPU 报文过多,导致stp报文被挤掉了,导致上行端口stp状态震荡。
设备版本存在问题,升级R1115 版本后故障没有再出现
✖