无
现场S10506上面插着防火墙插卡,之前可以正常识别,但是插拔一下后就无法识别了,插到别的设备上可以正常识别。
1、查看flash发现没有当前版本的bin文件:
Directory of flash:/
0 -rw- 35668992 Nov 15 2019 16:39:15 s10500-cmw520-r1208p09.bin
1 drw- - Nov 15 2019 16:54:13 logfile
2 drw- - Nov 15 2019 16:54:13 seclog
3 -rw- 16744 Apr 29 2020 11:32:32 startup.cfg
4 -rw- 102784 Apr 29 2020 11:31:59 config.cwmp
5 -rw- 10015304 Apr 29 2020 11:28:43 default.diag
6 -rw- 1364 Apr 29 2020 11:32:17 system.xml
7 -rw- 6813126 May 08 2020 11:04:24 20200508.diag
2、将bin文件导入设备后,插拔防火墙插卡,依然无法识别:
<s10508>dir
Directory of flash:/
0 drw- - Nov 15 2019 16:54:13 logfile
1 drw- - Nov 15 2019 16:54:13 seclog
2 -rw- 16744 Apr 29 2020 11:32:32 startup.cfg
3 -rw- 102784 Apr 29 2020 11:31:59 config.cwmp
4 -rw- 10015304 Apr 29 2020 11:28:43 default.diag
5 -rw- 1364 Apr 29 2020 11:32:17 system.xml
6 -rw- 10351376 May 08 2020 11:06:47 20200508.diag
7 -rw- 37054464 May 08 2020 13:53:25 s10500-cmw520-r1210p03.bin
125349 KB total (67657 KB free)
3、查看boot-loader发现启动文件与当前版本文件不一致:
<s10508>display version
H3C Comware Platform Software
Comware Software, Version 5.20, Release 1210P03
Copyright (c) 2004-2017 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
H3C S10508-V uptime is 101 weeks, 3 days, 3 hours, 5 minutes
<s10508>display boot-loader
The primary app to boot of board 5 at this time is: flash:/S10500-CMW520-R1208P09.BIN
The primary app to boot of board 5 at next time is: flash:/s10500-cmw520-r1210p03.bin
The slave app to boot of board 5 at next time is: flash:/s10500-cmw520-r1208.bin
板卡识别的两个条件,flash中要有相关的bin文件,boot-loader中的版本文件要与当前设备运行的版本文件保持一致。