Print

Brocade SAN Switch panic due to high amount of link failures

2026-08-12 发表

问题描述

  • Switch sees many link failures with error messages in errdump -a referencing a port with many link filures.
2025/12/04-09:17:12 (AEDT), [MAPS-1003], 47845877, FID 128 | PORT 0/12, WARNING, faba, faba int2 q5:2,U-Port 12, COndition=ALL_PORTS(LF/min>5), Current Value:[LF, 160 LFs], RuleName=defALL_PORTSLF_5, Dashboard Category=Port Health, Quiet Time=None.
2025/12/04-09:18:12 (AEDT), [MAPS-1003], 47845878, FID 128 | PORT 0/12, WARNING, faba, faba int2 q5:2, U-Port 12, COndition=ALL_PORTS(LF/min>5), Current Value:[LF, 195 LFs], RuleName=defALL_PORTSLF_5, Dashboard Category=Port Health, Quiet Time=None.

过程分析

Link failures on a single port on the switch causing a switch panic.

解决方法

Disable port and resolve physical layer issues prior to enabling the port.