问题描述
Some or all disks have abnormal or unexpected names:
- On ONTAP System Manager:


过程分析
This issue may be the result of shelf configuration changes, such as:
- Adding/removing shelves to the cluster
- Modifying shelf names
- Having a duplicate shelf id in the shelves configuration
解决方法
- Perform a takeover and giveback of the node that displays the abnormal disk names
- Perform a takeover and giveback of the HA partner of the node you gave back in step 1
- Confirm if the abnormal names have been replaced by the expected disk names via ONTAP System Manager, or via ONTAP CLI by running:
cluster::> run * sysconfig -r
Example:
Abnormal disk names (before takeover and giveback of both nodes):
1.SHFHU2128000117.3
1.SHFHU2128000117.5
Expected disk names (after the takeover and giveback of both nodes):