Disks have abnormal disk names

2026-08-12 发表

问题描述

Some or all disks have abnormal or unexpected names:

  • On ONTAP System Manager:

过程分析

This issue may be the result of shelf configuration changes, such as:

  • Adding/removing shelves to the cluster
  • Modifying shelf names
  • Having a duplicate shelf id in the shelves configuration

解决方法

  1. Perform a takeover and giveback of the node that displays the abnormal disk names
  2. Perform a takeover and giveback of the HA partner of the node you gave back in step 1
  3. Confirm if the abnormal names have been replaced by the expected disk names via ONTAP System Manager, or via ONTAP CLI by running:

cluster::> run * sysconfig -r

 



Example:
Abnormal disk names (before takeover and giveback of both nodes):
1.SHFHU2128000117.3
1.SHFHU2128000117.5


Expected disk names (after the takeover and giveback of both nodes):

 

0b.01.3