Print
知

NetApp FAS系列命令行升级步骤

4天前 发表

问题描述

NetApp FAS系列升级步骤

过程分析

NetApp FAS系列升级步骤

解决方法

rows 0

set -privilege advanced

node show -fields serialnumber,node,systemid,model,vendor,health,uptime

license show         #确认两个节点序列号下均有协议许可。

storage failover show   #确认两个节点接管状态正常

ucadmin show      #确认node1和node2的端口信息一致。

network interface show    #确认所有端口均为up

network port show  

cluster ring show -online offline

cluster show

cluster ha show

node show -instance

system fru-check show 

system chassis show

system controller environment show

system controller service-event show

 

lun show -state !online

snapmirror show -healthy false

volume show -in-nvfailed-state true

volume show -is-inconsistent true

volume show -state !online,!restricted -size !"-"

vserver cifs check -status down #Requires ONTAP 9.5+

vserver cifs show -status-admin down

vserver fcp show -status-admin down

vserver iscsi show -status-admin down

vserver nfs show -access !true

 

重启 SP

然后takeover givebackup

FAS8200::> storage failover show

FAS8200::> cluster show

Node2上操作

FAS8200::> storage failover takeover -ofnode FAS8200-01

FAS8200::> storage failover giveback -ofnode FAS8200-01        归还

Node1上操作

FAS8200::> storage failover takeover -ofnode FAS8200-02

FAS8200::> storage failover giveback -ofnode FAS8200-02        归还

 

 

这个步骤控制器会重启

 

两个控制器都做完了,开始升级。

 

如果图形界面升级,不要做这个操作:

检查并关闭自动归还:

storage failover show -node * -field auto-giveback 

storage failover modify -node * -auto-giveback false