拓扑:如下图所示,DS03和DS04起了vrrp主备,分别于接入设备AS05和AS06互联.接入设备下接的是服务器.
CRC问题,
1.DS03和AS05
2.DS03和AS05
3.将DS03
将AS05
将DS03
4.更换AS05
5.将DS03
(1)前面的测试无法彻底排除以下已知问题的可能性:
S9500-CMW310-R1652P09
(2)前面的测试无法锁定故障点在DS03
----------------------------------------------
----------------------------------------------
1. 将AS-05
----------------------------------------------
----------------------------------------------
test lpu fa boardinterlpbk 0 1 1500 50 00000000
@
Slot 0 PP 0 and slot 1 PP 0 test fail, due to
23 normal 0 error 27 lost in 50 packets
Slot 0 PP 0 and slot 1 PP 1 forwarding path is OK
Slot 0 PP 1 and slot 1 PP 0 test fail, due to
20 normal 0 error 30 lost in 50 packets
Slot 0 PP 1 and slot 1 PP 1 forwarding path is OK
$$
test lpu fa boardinterlpbk 1 2 1500 50 00000000
@
Slot 1 PP 0 and slot 2 PP 0 test fail, due to
19 normal 0 error 31 lost in 50 packets
Slot 1 PP 0 and slot 2 PP 1 test fail, due to
23 normal 0 error 27 lost in 50 packets
Slot 1 PP 1 and slot 2 PP 0 forwarding path is OK
Slot 1 PP 1 and slot 2 PP 1 forwarding path is OK
$$
test lpu fa boardinterlpbk 1 3 1500 50 5a5a5a5a
@
Slot 1 PP 0 and slot 3 PP 0 test fail, due to
22 normal 0 error 28 lost in 50 packets
Slot 1 PP 0 and slot 3 PP 1 test fail, due to
20 normal 0 error 30 lost in 50 packets
Slot 1 PP 1 and slot 3 PP 0 forwarding path is OK
Slot 1 PP 1 and slot 3 PP 1 forwarding path is OK
$$
test lpu fa intloopback 1 1500 50 ffffffff
@
===== NetID 0 =====
The lpu FA internal loopback is abnormal!
===== NetID 1 =====
The lpu FA internal loopback is OK!
$$
FA芯片故障会导致报文错包或者报文直接被丢弃。因此当前1
SLOT 0硬件故障
解决方法: