现场是两台S12508F-AF设备堆叠, 版本为Version 7.1.070, Release 2710。
设备上之前配了很多resource-monitor来监控资源剩余情况,由于不再需要告警通知,所以使用undo resource-monitor resource命令用来取消资源告警通知的门限配置,但发现undo 后配置依然在,undo不了这个配置。
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]undo resource-monitor resource ac chassis 1 slot 2
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]dis cu | include resource-monitor
resource-monitor resource global_ecmp chassis 1 slot 0 cpu 0 by-percent minor-threshold 20 severe-threshold 5
resource-monitor resource ac chassis 1 slot 2 cpu 0 by-percent minor-threshold 20 severe-threshold 5
(1)
resource-monitor resource resource-name chassis chassis-number slot slot-number cpu cpu-number by-percent minor-threshold minor-threshold severe-threshold severe-threshold
在配置了低级别和高级别告警门限后,当资源剩余到达告警门限时,设备可以向NETCONF、SNMP、信息中心三个方向输出资源告警通知。例如:
resource-monitor resource ac chassis 1 slot 2 cpu 0 by-percent minor-threshold 20 severe-threshold 5
这条命令的功能是,配置设备在AC资源剩余20%的时候发送低级别告警通知,在剩余5%的时候发送高级别告警通知。
(2)
(3)
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]undo resource-monitor resource ac chassis 1 slot
2 cpu 0
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]dis cu | include resource-monitor
resource-monitor resource ac chassis 1 slot 2 cpu 0 by-percent minor-threshold 20 severe-threshold 5
但直接修改数值是可以的:
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]resource-monitor resource ac chassis 1 slot 2 cpu
0 by-percent minor-threshold 10 severe-threshold 8
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]dis cu | include resource-monitor
resource-monitor resource ac chassis 1 slot 2 cpu 0 by-percent minor-threshold 10 severe-threshold 8
远程时还请研发上来看了,研发也没有发现什么异常。
(4)
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]dis cu | include resource-monitor
resource-monitor resource ac chassis 1 slot 2 cpu 0 by-percent minor-threshold 10 severe-threshold 8
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]undo resource-monitor resource ac chassis 1 slot
2 cpu 0
[SZ-KS-HQIDC-ZWY-DSW.S12500-02]dis cu | include resource-monitor
resource-monitor resource ac chassis 1 slot 2 cpu 0 by-percent minor-threshold 20 severe-threshold
(1) R2710版本无法删除resource-monitor的告警门限配置,只能恢复到设备的缺省配置(缺省为在资源剩余20%的时候发送低级别告警通知,在剩余5%的时候发送高级别告警通知),该配置是缺省配置,没有影响。
(2) 如果现场要求一定要删除这些配置,可以将设备升级到R2712版本,在该版本上删除配置。
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作