S7003E----直连服务器
现场S7003E ,1/2/0/1~1/2/0/8 和2/2/0/1~2/2/0/8 连接浪潮服务器(NF8460M3),接口速率协商异常。
===============display device verbose===============
Slot Type State Subslot Soft Ver Patch Ver
1/0 LSQM1CGT24TSSA8 Master 0 S7000E-7585P06 None
1/1 LSQM1CGT24TSSA8 Standby 0 S7000E-7585P06 None
1/2 LSQM2GT48SA8 Normal 0 S7000E-7585P06 None
2/0 LSQM1CGT24TSSA8 Standby 0 S7000E-7585P06 None
2/1 LSQM1CGT24TSSA8 Standby 0 S7000E-7585P06 None
2/2 LSQM2GT48SA8 Normal 0 S7000E-7585P06 None
具体为:
2/2/0/1~2/2/0/8 :8个接口连接浪潮服务器均只能自协商为百兆。
将浪潮服务器连接到1/2/0/9及以后,2/2/0/9及以后 的端口均能自协商为千兆。将服务器更换到其他华为或我司低端接入交换机也可自协商为千兆速率
将自协商为百兆的接口,手动强制千兆全双工后接口down(服务器接口也手动强制)
笔记本电脑连接,异常接口,可自协商千兆。
[DMZ7003E-probe]bcm chass 2 slot 2 chip 0 ps
ena/ speed/ link auto STP lrn inter max loop
port link duplex scan neg? state pause discrd ops face frame back
ge0( 1) down - SW Yes Block None FA SGMII 9216
ge1( 2) up 100M FD SW Yes Forward None FA SGMII 9216
(1) 通过诊断信息,发现LSQM1CGT24TSSA8单板前八个口用的phy芯片跟其他端口不一样。LSQM2GT48SA8前八个口用的BCM54382,其余口用的BCM54282。
(2) 实验室本地用同样的网卡跟LSQM1CGT24TSSA8单板的1-8口对接,发现是可以正常协商成1000M的。
交换机侧
[NP-probe]bcm s 2 c 0 ps
ena/ speed/ link auto STP lrn inter max loop
port link duplex scan neg? state pause discrd ops face frame back
ge0( 1) down - SW Yes Block TX RX None FA SGMII 9216
ge1( 2) up 1G FD SW Yes Forward None FA SGMII 9216
ge2( 3) down - SW Yes Block TX RX None FA SGMII 9216
ge3( 4) down - SW Yes Block None FA SGMII 9216
ge4( 5) down - SW Yes Block TX RX None FA SGMII 9216
ge5( 6) down - SW Yes Block TX RX None FA SGMII 9216
ge6( 7) down - SW Yes Block TX RX None FA SGMII 9216
ge7( 8) down - SW Yes Block TX RX None FA SGMII 9216
ge8( 9) down - SW Yes Block TX RX None FA SGMII 9216
ge9( 10) down - SW Yes Block TX RX None FA SGMII 9216
ge10( 11) down - SW Yes Block TX RX None FA SGMII 9216
ge11( 12) down - SW Yes Block TX RX None FA SGMII 9216
ge12( 13) down - SW Yes Block TX RX None FA SGMII 9216
ge13( 14) down - SW Yes Block TX RX None FA SGMII 9216
ge14( 15) down - SW Yes Block TX RX None FA SGMII 9216
ge15( 16) up 1G FD SW Yes Forward None FA SGMII 9216
ge16( 17) up 1G FD SW No Forward None F SGMII 9216 PHY
ge17( 18) up 1G FD SW Yes Forward None FA SGMII 9216
ge18( 19) up 1G FD SW No Forward None F SGMII 9216 PHY
ge19( 20) up 1G FD SW No Forward None F SGMII 9216 PHY
ge20( 21) down - SW Yes Block TX RX None FA SGMII 9216
[NP-probe]dis dev
Slot No. Brd Type Brd Status Subslot Sft Ver Patch Ver
0 LSQM1MPUS06B8 Master 0 S7000E-7585P07 None
1 LSQM1MPUS06B8 Standby 0 S7000E-7585P07 None
2 LSQM2GT48SA0 Normal 0 S7000E-7585P07 None
3 LSQM2GP48SA8 Normal 0 S7000E-7585P07 None
4 LSQM2GP24TSSA0 Normal 0 S7000E-7585P07 None
5 LSQM1TGS16FD0 Normal 0 S7000E-7585P07 None
6 LSQM2GP24TSSC8 Normal 0 S7000E-7585P07 None
7 NONE Absent 0 NONE None
(3) 排除了网卡的因素,所以只能是服务器或者是网卡型号的原因,导致对接协商速率异常。
更新的网卡版本
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作