本案例使用H3C S1850交换机部署snmpv3,同时在IMC纳管H3C S1850交换机,达到实时监控的效果。
S1850交换机的版本如下:
H3C Comware Platform Software
Comware Software, Version 5.20.99, Release 1102
Copyright (c) 2004-2017 New H3C Technologies Co., Ltd. All rights reserved.
H3C S1850-28P uptime is 0 week, 1 day, 11 hours, 54 minutes
H3C S1850-28P
128M bytes DRAM
32M bytes Flash Memory
Config Register points to Flash
Hardware Version is Ver.A
Bootrom Version is 102
[SubSlot 0] 24GE+4SFP Hardware Version is Ver.A
IMC版本如下:
PLAT 7.3 E0506P03
1、在S1850交换机部署SNMPV3
2、在IMC纳管S1850交换机后,设置SNMPV3的用户名、认证密码、加密密码,测试SNMPV3
3、确保S1850交换机与IMC的路由可达
1、S1850 SNMPV3的配置如下:
snmp-agent
snmp-agent sys-info version v2c v3
snmp-agent mib-view included iso iso
snmp-agent group v3 ddk read-view iso write-view iso notify-view iso
snmp-agent usm-user v3 ddk ddk authentication-mode md5 wjn201412 privacy-mode aes128 wjn201412
snmp-agent trap enable
snmp-agent target-host trap address udp-domain 10.190.8.252 params securityname wjn201412 v3
snmp-agent trap source Vlan-interface 400
2、IMC的纳管配置如下:
设置用户名、认证密码、加密密码、认证参数:
测试SNMPV3通过:
至此,S1850交换机SNMPV3的典型组网配置案例(与IMC联动)已完成!