DR2000平台及组件安装
安装DR2000组件时,软件自动识别的IPV4地址为网卡的IPV6的地址
网卡的配置如下:
从日志来看,在安装DR2000 的时候,只有IPv6的地址,没有IPv4的地址。在装好DR2000之后,安装EIA组件之前才进行的设置,而EIA组件安装的时候会直接获取安装平台时获取到的IP地址。
Replacement Variables: {${COUNTRY}=CN, ${DATABASE_ADDRESS}=127.0.0.1, ${DATABASE_ADMIN_PASSWORD_ESCAPE}={PROTECTED}, ${DATABASE_ADMIN_PASSWORD}={PROTECTED}, ${DATABASE_ADMIN_USERNAME}=sa, ${DATABASE_PORT}=1433, ${DATABASE_TYPE}=SQLServer, ${DATAFILE_DIR}=C:\Program Files\imcdata, ${DEPLOY_IP}=127.0.0.1, ${HTTPS_PORT}=8443, ${HTTP_PORT}=8080, ${INSTALL_DESTINATION_DIR}=C:\Program Files\iMC, ${INSTANCE_NAME}=, ${LANGUAGE_U}=zh, ${LANGUAGE}=zh, ${LOCAL_IP_0}=fe80:0:0:0:4036:b6c7:10cc:ef10%12, ${LOCAL_IP_1}=fe80:0:0:0:6cb6:8d4d:cb7a:368c%13, ${LOCAL_IP_2}=fe80:0:0:0:a9e7:45ea:cb0d:75c2%14, ${LOCAL_IP_3}=fe80:0:0:0:2c7e:d154:e211:e82a%15, ${LOCAL_IP_COUNT}=4, ${MASTER_IP}=localhost, ${SERVER_TYPE}=Master, ${SQLSERVER_COLLATE_CS}=COLLATE Chinese_PRC_CS_AS_KS_WS, ${SQLSERVER_COLLATE}=COLLATE Chinese_PRC_CI_AS, ${iMC-PLAT['DEPLOY_IP']}=127.0.0.1}
1.直接更改为正确的ipv4地址不影响组件部署;
2.卸载DR2000平台,重启确保地址设置正确后再重新安装,则安装组件时可识别正确的IP地址。
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作