交换机上出现permission denied日志,看配置里面指定了该地址为接收告警的目的主机,IMC会两小时登录一下设备进行信息收集,看打印的deny日志时间也是符合时间。
#
acl basic 2999
rule 0 permit vpn-instance management source 10.12.60.0 0.0.0.255
#
%Dec 5 04:35:26:156 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 04:35:26:156 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 04:35:26:157 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 06:35:42:891 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 06:35:42:891 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 06:35:42:891 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 08:35:45:011 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 08:35:45:011 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 08:35:45:011 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
%Dec 5 04:35:26:156 2021 StorA_S6900_IRF_6 SNMP/5/SNMP_GETDENY: -IPAddr=10.12.60.240-SecurityName=Pdzwy2015-SecurityModel=SNMPv2c-OP=GET-Node=; Permission denied.
其中get-node后应该有OID节点号,此处为空,snmp不识别,就打印错误,怀疑是IMC侧问题,iMC升级至7.3 E0705P12可以解决