设备:S6850
版本:R2612
设备批量下发acl时导致堆叠主设备异常重启,重启原因记录为kernel异常重启:
Slot 1:
Uptime is 0 weeks,0 days,0 hours,14 minutes
S6800-54QF with 2 Processor
BOARD TYPE: S6800-54QF
DRAM: 2048M bytes
FLASH: 512M bytes
PCB 1 Version: VER.A
FPGA Version: NONE
Bootrom Version: 158
CPLD 1 Version: 002
CPLD 2 Version: 001
Release Version: H3C S6800-54QF-2612
Patch Version: None
Reboot Cause: KernelAbnormalReboot
[SubSlot 0] 48SFP Plus+6QSFP Plus
设备上相关日志如下:
%Nov 25 15:31:12:242 2021 NJ_DC_DS_OFF_6800 SHELL/6/SHELL_CMD: -Slot=1; -Line=vty0-IPAddr=172.16.188.73-User=admin; Command is rule 1140 permit ip destination 172.16.164.201 0
%Nov 25 15:31:18:184 2021 NJ_DC_DS_OFF_6800 SHELL/6/SHELL_CMD: -Slot=1; -Line=vty0-IPAddr=172.16.188.73-User=admin; Command is rule 1141 permit ip destination 172.22.48.48 0
%Nov 25 15:31:26:993 2021 NJ_DC_DS_OFF_6800 SHELL/6/SHELL_CMD: -Slot=1; -Line=vty0-IPAddr=172.16.188.73-User=admin; Command is rule 1142 permit ip destination 172.22.48.49 0
%Nov 25 15:31:32:847 2021 NJ_DC_DS_OFF_6800 SHELL/6/SHELL_CMD: -Slot=1; -Line=vty0-IPAddr=172.16.188.73-User=admin; Command is rule 1143 permit ip destination 172.22.48.51 0
%Nov 25 15:31:41:265 2021 NJ_DC_DS_OFF_6800 HA/5/HA_STANDBY_TO_MASTER: Standby board in slot 2 changed to master.
实验室拷机复现定位为当前版本下的acl批量下发过程触发acl搬移过程代码处理问题,在R2612P02H21版本解决。