暂无
==== display power ====
Power supply policy : Enabled
Surplus sleeping : Disabled
Power modules installed : 16
Power modules usable : 16
Total power : 48000W
Redundant power : 0W
Sleeping power : 0W
Available power : 48000W
Allocated power : 18620W
Remaining power : 29380W
PowerID State InPower(W) Current(A) Voltage(V) OutPower(W) Type
1 Normal 3000 0.00 52.95 0.00 PSR3000-54A
2 Normal 3000 0.75 52.90 39.67 PSR3000-54A
3 Normal 3000 18.25 52.94 966.15 PSR3000-54A
4 Normal 3000 0.50 52.88 26.44 PSR3000-54A
5 Normal 3000 1.50 52.87 79.30 PSR3000-54A
6 Normal 3000 27.75 52.88 1467.42 PSR3000-54A
7 Normal 3000 0.25 51.51 12.87 PSR3000-54A
8 Normal 3000 11.75 52.98 622.51 PSR3000-54A
9 Normal 3000 10.75 52.93 568.99 PSR3000-54A
10 Normal 3000 41.75 52.92 2209.41 PSR3000-54A
11 Normal 3000 0.75 52.93 39.69 PSR3000-54A
12 Normal 3000 0.75 52.87 39.65 PSR3000-54A
13 Normal 3000 0.75 52.89 39.66 PSR3000-54A
14 Normal 3000 26.75 53.01 1418.01 PSR3000-54A
15 Normal 3000 28.00 52.99 1483.72 PSR3000-54A
16 Normal 3000 28.50 53.00 1510.50 PSR3000-54A
电源都支持输出均流的,现场这个情况,应该是某一个电源输出电压偏低,会导致均流整体被拉偏。
就变成当前不均衡的情况了。但是这种不影响使用和设备的正常运行。只是会导致出现不均衡的情况。
如果需要恢复,就需要把输出电压低,即异常的那个电源找出来,进行更换。
一台设备中有16pcs电源,其中有1pcs输出电压异常偏低了就会导致这个情况
把这1pcs拔出来,如果这台设备恢复正常均流了,就说明这pcs有问题
因为power 7的输出电压最低:
7 Normal 3000 0.25 51.51 12.87 PSR3000-54A
更换power 7 电源模块
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作