某局点修改接口下flow-interval采样时间为5s但是display interface看仍为300s
interface Ten-GigabitEthernet1/0/8
port link-mode bridge
description CAS06
port link-type trunk
port trunk permit vlan 1 91 888 to 896 901 to 905 911 to 918 930 to 931 940 to 941 943 to 948
flow-interval 5
port link-aggregation group 8
Ten-GigabitEthernet1/0/8
Current state: UP
Line protocol state: UP
IP packet frame type: Ethernet II, hardware address: 74d6-cb84-fab7
Description: CAS06
Bandwidth: 10000000 kbps
…
Port priority: 0
Last link flapping: 2 weeks 4 days 8 hours 59 minutes
Last clearing of counters: 11:06:40 Wed 03/09/2022
Current system time:2022-03-10 09:22:30
Last time when physical state changed to up:2022-02-20 00:23:30
Last time when physical state changed to down:2022-02-20 00:23:30
Peak input rate: 20962876 bytes/sec, at 2022-03-10 05:51:03
Peak output rate: 16087333 bytes/sec, at 2022-03-10 02:58:49
Last 300 seconds input: 962 packets/sec 362991 bytes/sec 0%
Last 300 seconds output: 1155 packets/sec 590743 bytes/sec 0%
Input (total): 96882069 packets, 31329779020 bytes
96826652 unicasts, 37420 broadcasts, 17997 multicasts, 0 pauses
怀疑是显示错误,但新版本说明书中没有相关已知问题。
经确认,R6329之前的版本端口下配置flow-interval后实际已经生效,但是display interface 显示的Last 300 seconds 显示错误,错误地按照flow-interval全局配置的时间(300s)显示,现场可升级至R6329版本解决。