设备型号为S12504G-AF,版本为R7596P09设备,现场两台S125G堆叠,1框2框分别通过聚合对接华为设备,S125G与华为设备通过三层聚合子接口互联,建立BGP邻居,并配置BGP与BFD联动,相关配置如下:
bgp 125000
#
ip vpn-instance 5G_MEC
peer 1.39.8.245 as-number 65398
peer 1.39.8.245 description To-HNLT-RD-MCR-5G_MEC
peer 1.39.8.245 bfd single-hop
peer 1.39.8.249 as-number 65398
peer 1.39.8.249 description To-HNLT-HX-MCR-5G_MEC
peer 1.39.8.249 bfd single-hop
#
address-family ipv4 unicast
aggregate 1.39.8.0 255.255.255.0
import-route direct
peer 1.39.8.245 enable
peer 1.39.8.245 route-policy MCR_v4_5G_MEC_OUT export
peer 1.39.8.249 enable
peer 1.39.8.249 route-policy MCR_v4_5G_MEC_OUT export
现场发现BFD会话持续震荡:
%Apr 29 08:28:26:501 2022 S12500G_IRF2 BGP/5/BGP_STATE_CHANGED: BGP.MEC_N6: 100.64.0.37 state has changed from OPENCONFIRM to ESTABLISHED.
%Apr 29 08:28:26:506 2022 S12500G_IRF2 BFD/5/BFD_CHANGE_FSM: Sess[100.64.0.38/100.64.0.37, LD/RD:4339/34855, Interface:RAGG1.4094, SessType:Ctrl, LinkType:INET], Ver:1, Sta: DOWN->INIT, Diag: 0 (No Diagnostic)
%Apr 29 08:28:27:563 2022 S12500G_IRF2 BFD/5/BFD_CHANGE_FSM: Sess[100.64.0.38/100.64.0.37, LD/RD:4339/34855, Interface:RAGG1.4094, SessType:Ctrl, LinkType:INET], Ver:1, Sta: INIT->UP, Diag: 0 (No Diagnostic)
%Apr 29 08:28:28:061 2022 S12500G_IRF2 BGP/5/BGP_STATE_CHANGED: BGP.5G_MEC: 1.39.8.245 state has changed from OPENCONFIRM to ESTABLISHED.
%Apr 29 08:28:28:062 2022 S12500G_IRF2 BFD/5/BFD_CHANGE_FSM: Sess[1.39.8.246/1.39.8.245, LD/RD:4340/251662359, Interface:RAGG2.839, SessType:Ctrl, LinkType:INET], Ver:1, Sta: DOWN->UP, Diag: 0 (No Diagnostic)
%Apr 29 08:28:28:091 2022 S12500G_IRF2 BFD/5/BFD_CHANGE_FSM: Sess[1.39.8.250/1.39.8.249, LD/RD:4336/34853, Interface:RAGG1.839, SessType:Ctrl, LinkType:INET], Ver:1, Sta: UP->DOWN, Diag: 3 (Neighbor Signaled Session Down)
%Apr 29 08:28:28:100 2022 S12500G_IRF2 BGP/5/BGP_STATE_CHANGED: BGP.5G_MEC: 1.39.8.249 state has changed from ESTABLISHED to IDLE for session down event received from BFD.
%Apr 29 08:28:28:100 2022 S12500G_IRF2 BGP/5/BGP_STATE_CHANGED_REASON: BGP.5G_MEC: 1.39.8.249 state has changed from ESTABLISHED to IDLE. (Reason: a session down event was received from BFD, Error code: Send Notificationcode 6/0)
%Apr 29 08:28:28:163 2022 S12500G_IRF2 BFD/5/BFD_CHANGE_FSM: Sess[1.90.48.254/1.90.48.253, LD/RD:4334/34854, Interface:RAGG1.837, SessType:Ctrl, LinkType:INET], Ver:1, Sta: UP->DOWN, Diag: 3 (Neighbor Signaled Session Down)
原因是BFD存在配置限制:三层聚合接口/子接口不支持与BFD功能联动。
虽然通过修改设备模式为expert专家模式后,设备可以开启硬件BFD功能,从而支持与三层聚合子接口联动,现场修改设备工作模式并保存配置重启后发现,主框的BFD会话正常,不会震荡,但是备框的BFD会话则一直无法UP:
1框为主时:
<S12500G_IRF2>dis bfd session
Total Session Num: 7 Up Session Num: 3 Init Mode: Active
IPv4 session working in control packet mode:
LD/RD SourceAddr DestAddr State Holdtime Interface
4097/0 11.11.11.1 11.11.11.2 Down / RAGG63
4098/34817 100.64.0.38 100.64.0.37 Up 2000ms RAGG1.4094
4099/34818 1.39.8.250 1.39.8.249 Up 2000ms RAGG1.839
4100/34819 1.90.48.254 1.90.48.253 Up 2000ms RAGG1.837
4101/0 100.64.0.34 100.64.0.33 Down / RAGG2.4094
4102/0 1.39.8.246 1.39.8.245 Down / RAGG2.839
4103/0 1.90.48.250 1.90.48.249 Down / RAGG2.837
2框为主时:
<S12500G_IRF2>dis bfd session
Total Session Num: 7 Up Session Num: 3 Init Mode: Active
IPv4 session working in control packet mode:
LD/RD SourceAddr DestAddr State Holdtime Interface
4104/0 11.11.11.2 11.11.11.1 Down / RAGG63
4105/0 100.64.0.38 100.64.0.37 Down / RAGG1.4094
4106/0 1.39.8.250 1.39.8.249 Down / RAGG1.839
4107/0 1.90.48.254 1.90.48.253 Down / RAGG1.837
4108/251662337 1.39.8.246 1.39.8.245 Up 2000ms RAGG2.839
4109/251662338 1.90.48.250 1.90.48.249 Up 2000ms RAGG2.837
4110/251662339 100.64.0.34 100.64.0.33 Up 2000ms RAGG2.4094
修改为专家模式后,虽然能支持聚合子接口,但也存在限制,不支持VPN。硬件BFD下会选举一块接口板做为会话维护板,现网1框为主时选的是1框堆叠板,2框为主时选的是2框堆叠板,对于维护板自己的会话,底层有VPN信息,BFD状态正常,而对于非维护板,BFD报文需要送到维护板处理,由于上述限制会丢失VPN信息,导致BFD状态异常。
建议现网使用默认standard模式(注意调整系统模式需要保存配置并整框重启),即软件BFD实现方式,并通过vlan方式对接。