暂无,两台设备做堆叠
暂无
现场使用EC类 单板端口做堆叠口,发生异常分裂
EC单板做堆叠口,容易出现堆叠口有错包后触发ibod流程,导致跨框流程丢包。当堆叠口收到超小帧,芯片尝试会用ibod动作修复
==== display irf cOnfiguration====
MemberID NewID IRF-Port1 IRF-Port2
1 1 disable Ten-GigabitEthernet1/2/0/23 Ten-GigabitEthernet1/2/0/24
2 2 Ten-GigabitEthernet2/2/0/23 disable
Ten-GigabitEthernet2/2/0/24
===============display device verbose===============
1/2 LSUM1TGS24EC0 Normal 0 S10500X-7624P12 None
2/2 LSUM1TGS24EC0 Normal 0 S10500X-7624P12 None
Ten-GigabitEthernet2/2/0/23
Current state: UP
Input: 880 input errors, 878 runts, 0 giants, 0 throttles
2 CRC, 0 frame, - overruns, 1 aborts
- ignored, - parity errors
==== display hardware internal diag hardware-diag-action information chassis 1 slot 6 ====
--------------------Executed action records:--------------------
Chassis 1, Slot 2:
1. 2022-04-20, 21:53:20 hot-rebooted by AI.
reason:SIBOD_ERR. chip 255: the action executed 1 times.
将堆叠口配置在非EC类的接口板上