不涉及
两台同型号同版本的S6520X-54QC-EI用37和38口堆叠,配置堆叠后一直报桥mac一致,导致堆叠无法成功
建立堆叠是提示如下报错:
[H3C-if-range]display diagnostic-%Jan 4 19:09:25:746 2013 H3C STM/4/STM_SAMEMAC: Failed to stack because of the same bridge MAC addresses.
1、型号均是S6520X-54QC-EI的,版本都是官网最新的6533版本,软硬件方面没问题
2、堆叠后用irf mac-address指令重新指定备件的桥mac地址为bc22-4724-7cb9,与主机的bc22-4724-7ca9不一致;重新配置堆叠,重启备机后还irf系统还是无法建立,依旧报地址一致;至此现象比较奇怪了
主机:
===============display irf===============
MemberID Role Priority CPU-Mac Description
*+1 Master 32 f010-90db-7402 ---
--------------------------------------------------
* indicates the device is the master.
+ indicates the device through which the user logs in.
The bridge MAC of the IRF is: bc22-4724-7ca9
Auto upgrade : yes
Mac persistent : 6 min
Domain ID : 0
备机
[H3C-if-range]dis irf
MemberID Role Priority CPU-Mac Description
*+2 Master 1 f010-90db-7403 ---
--------------------------------------------------
* indicates the device is the master.
+ indicates the device through which the user logs in.
The bridge MAC of the IRF is: bc22-4724-7cb9
Auto upgrade : yes
Mac persistent : always
Domain ID : 0
[H3C]%Jan 4 18:57:49:798 2013 H3C STM/4/STM_SAMEMAC: Failed to stack because of the same bridge MAC addresses.
3、再通过仔细分析诊断发现,两台设备的SN号和物理MAC地址均一致,这显然是不合理的,怀疑两台设备有存在假货;经再次确认,诊断信息里的SN码和设备机框所贴SN码均不一致,两台都应该是假货
主机:
===============display device manuinfo===============
Slot 1 CPU 0:
DEVICE_NAME : S6520X-54QC-EI
DEVICE_SERIAL_NUMBER : 210235A2CJ6222V0G0HP
MAC_ADDRESS : BC22-4724-7CA9
MANUFACTURING_DATE : 2022-02-12
VENDOR_NAME : H3C
备机:
===============display device manuinfo===============
Slot 2 CPU 0:
DEVICE_NAME : S6520X-54QC-EI
DEVICE_SERIAL_NUMBER : 210235A2CJ6222V0G0HP
MAC_ADDRESS : BC22-4724-7CA9
MANUFACTURING_DATE : 2022-02-12
VENDOR_NAME : H3C
替换两台原厂设备后堆叠正常。
✖
案例意见反馈
亲~登录后才可以操作哦!