两台S10504 (V5)设备堆叠
打印心跳超时:
%May 18 04:45:04:871 2022 SZB14-3F-IVS-CSW SHELL/6/SHELL_CMD: -Task=vt5-IPAddr=10.26.33.123-User=yunwei; Command is quit
%May 18 04:45:09:696 2022 SZB14-3F-IVS-CSW SHELL/6/SHELL_CMD: -Task=vt5-IPAddr=10.26.33.123-User=yunwei; Command is dis diagnostic-information
%May 18 04:45:19:922 2022 SZB14-3F-IVS-CSW STM/2/STM_LINK_STATUS_TIMEOUT:
IRF port 2 is down because heartbeat timed out.
%May 18 04:45:19:923 2022 SZB14-3F-IVS-CSW STM/3/STM_LINK_STATUS_DOWN:
IRF port 2 is down.
%May 18 04:45:19:924 2022 SZB14-3F-IVS-CSW STM/2/STM_LINK_STATUS_TIMEOUT: -Chassis=2-Slot=4;
IRF port 1 is down because heartbeat timed out.
%May 18 04:45:19:925 2022 SZB14-3F-IVS-CSW STM/3/STM_LINK_STATUS_DOWN: -Chassis=2-Slot=4;
IRF port 1 is down.
%May 18 04:45:21:218 2022 SZB14-3F-IVS-CSW STM/6/STM_LINK_STATUS_UP:
IRF port 2 is up.
%May 18 04:45:21:219 2022 SZB14-3F-IVS-CSW STM/6/STM_LINK_STATUS_UP: -Chassis=2-Slot=4;
IRF port 1 is up.
现场打印堆叠的心跳报文超时:
irf-port 1/1
port group interface Ten-GigabitEthernet1/6/0/3 mode enhanced
#
irf-port 1/2
port group interface Ten-GigabitEthernet1/6/0/4 mode enhanced
#
irf-port 2/1
port group interface Ten-GigabitEthernet2/6/0/3 mode enhanced
#
irf-port 2/2
port group interface Ten-GigabitEthernet2/6/0/4 mode enhanced
#
现场是环形堆叠
对于框式设备,2台设备环形堆叠有限制,不建议两台设备使用环形堆叠;查看官网 105
的手册,官网手册有说明,2台设备不能使用环形堆叠
将环形堆叠修改为 链堆后恢复