第三方百兆模块在设备上无法识别
先在接口配置speed100后能再插入模块能正常使用,设备掉电重启后speed100命令丢失
查看接口信息提示不支持,所以在正常插入模块时,无法强制速率使其正常
GigabitEthernet1/0/1 transceiver manufacture information:
The transceiver does not support this function.
[H3C]dis transceiver interface g1/0/1
GigabitEthernet1/0/1 transceiver information:
Transceiver Type : 1000_xxx
Connector Type : LC
Wavelength(nm) : 1550
Transfer Distance(km) : 20(SMF)
Digital Diagnostic Monitoring : YES
Vendor Name : xxx
GigabitEthernet1/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp.(¡ãC) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
42 3.35 22.13 -14.06 -3.43
Alarm thresholds:
Temp.(¡ãC) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 95 3.90 60.00 0.00 -2.00
Low -20 2.90 0.00 -22.01 -10.00
插入模块前,先强制速率,再插入模块能正常使用
#
interface GigabitEthernet1/0/1
speed 100
#
保存配置重启后
Saved the current configuration to mainboard device successfully.
This command will reboot the device. Continue? [Y/N]:y
对应接口speed100命令消失
由于设备重启会检测对应接口和模块,发现模块不适配,所以无法下发命令
正与插上模块时无法强制速率的现象一致
#
interface GigabitEthernet1/0/1
#
建议使用原厂适配模块