服务器(1.1.1.1)-- GigabitEthernet1/0/1交换机GigabitEthernet1/0/2--录像机(1.1.1.2)
交换机空配置,录像机向服务器发送UDP视频流,出现大量丢包,流统也能统计到丢包
1、排查诊断发现有缓存不足导致的丢包
===============tail-drop reg switch 1 0 read 2b40174===============
Read Switch Reg 0x2b40174 SUCCESS [data = 0x273]
31~28 27~24 | 23~20 19~16 | 15~12 11~8 | 7~ 4 3~ 0
---------------------------------------------------
0000 0000 | 0000 0000 | 0000 0010 | 0111 0011
===============tail-drop reg switch 1 1 read 2b40174===============
Read Switch Reg 0x2b40174 FAIL [data = 0x0]
===============tail-drop reg switch 1 0 read 2b40154===============
Read Switch Reg 0x2b40154 SUCCESS [data = 0x273]
31~28 27~24 | 23~20 19~16 | 15~12 11~8 | 7~ 4 3~ 0
---------------------------------------------------
0000 0000 | 0000 0000 | 0000 0010 | 0111 0011
===============tail-drop reg switch 1 1 read 2b40154===============
Read Switch Reg 0x2b40154 FAIL [data = 0x0]
怀疑现场有突发或者存在高带宽打低带宽的问题,让现场先配置burst-mode enable观察,或者将100M接口关闭,现场配置burst-mode enable之后发现还是有丢包
2、继续让现场关闭100接口,或者替换成1G接口,避免出现高打低的现象。
Interface
Link Speed Duplex Type PVID
Description
GE1/0/1
UP 1G(a) F(a) A
1 GE1/0/2
UP 1G(a) F(a) A
1 GE1/0/3
UP 100M(a) F(a) A 1
GE1/0/4
UP 100M(a) F(a) A 1
GE1/0/5
UP 100M(a) F(a) A 1 3、现场先将3口和4口关闭了,但是问题还是存在,继续观察接口流量,发现5口这个100M接口流量很是异常,这个接口只有100M,但是流量却是最多的,于是让客户务必将该接口替换掉或者关闭掉,现场将3、4、5口都关闭后我,问题解决。 4、100M的流量哪里来,只能是其他1G口进来的发给100M的,这种千兆口打百兆口容易出现缓存不足的问题,从而影响其他接口
1、先配置burst-mode enable观察是否解决
2、未解决继续关闭100M接口或者降100M接口更改成1G接口,避免出现高打低的问题