HPE ProLiant服务器使用hpssascripting批量配置Raid
目前hpssascripting 工具存在于hpssacli中
1、安装hpssacli
2、安装后进入如下目录
3、运行命令查看当前可用配置参数
4、抓取当前配置文件 命名为config.ini
5、将配置导出修改配置如下,增加array B 和spare 盘。
; Date captured: Wed Sep 14 17:28:45 2016
; Version: 2.40.13.0
Action= Configure
Method= Custom
; __________________________ Controller Specifications SLOT 0 ________________________________
;
; Controller HPE Smart Array P420i, FirmwareVersion 7.02, License Keys Supported
; SerialNumber 0014380217F5E20
; DriverName hpsa
; DriverVersion 3.4.4
; SSDSmartPath Supported
COntroller= SLOT 0
ReadCache= 10
WriteCache= 90
RebuildPriority= High
ExpandPriority= Medium
SurfaceScanMode= Idle
SurfaceScanDelay= 3
DriveWriteCache= Disabled
NoBatteryWriteCache= Disabled
LicenseKey= 324Q6-JDL97-JMQDK-7XW2Q-DS5J6
; LicenseKeyType= Flex License
MNPDelay= 60
IRPEnable= Disabled
DPOEnable= Disabled
ElevatorSortEnable= Enabled
QueueDepth= Automatic
PredictiveSpareActivation= Disable
; Array Specifications
;Array= A
; Array Drive Type is Solid State SATA
; Array Free Space 0 GBytes
; 2I:1:1 (120.0 GB, Solid State SATA)
;Drive= 2I:1:1
;SSDSmartPath= Enable
;OnlineSpare= No
; Logical Drive Specifications
;LogicalDrive= 1
;RAID= 0
;Size= 114439
; SizeBlocks= 234371520
;Sectors= 32
;StripSize= 256
; VolumeUniqueID= 600508B1001C9161B6D3BD0DA9631251
; Array Specifications
Array= B
; Array Drive Type is SAS
; Array Free Space 0 GBytes
; 2I:1:3 (300 GB, SAS), 2I:1:4 (300 GB, SAS)
Drive= 2I:1:3, 2I:1:4
OnlineSpare= 1I:1:5
; Logical Drive Specifications
LogicalDrive= 2
RAID= 1
Size= 286070
; SizeBlocks= 585871964
Sectors= 32
StripSize= 256
Caching= Enabled
; VolumeUniqueID= 600508B1001C3DFF457C263420D9C2C7
6、再将配置改名后,上传到服务器
之后将新的阵列配置文件改名为arrayB_raid_spare,使用如下命令创建当前配置。
7、之后验证当前结果,进入hpssacli中输入如下命令
8、配置成功,通过此配置文件,可以批量配置其他机器。
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作