型号及版本:S12508G-AF-7596P07
问题描述:使用PC通过snmp读取设备信息,无法获取,PC和设备之间ping测是通的。
过程分析:
PC上snmp读取设备信息,回显如下
debug看有提示VACM报错
*Sep 14 19:03:40:255 2022 ZW-HX-S12508-B3B4-IRF SNMP/7/VBLIST: -MDC=1;
mib-2:
*Sep 14 19:03:40:255 2022 ZW-HX-S12508-B3B4-IRF SNMP/7/STACK_INFO: -MDC=1;
Process request
*Sep 14 19:03:40:257 2022 ZW-HX-S12508-B3B4-IRF SNMP/7/STACK_ERROR: -MDC=1;
Failed to check VACM (error code: 130)
设备SNMP支持的访问控制方式包括VACM和RBAC两种,查询发现设备默认mib view 之前被客户误删,重新添加后回复
[DR2]dis snmp-agent mib-view
View name: ViewDefault
MIB Subtree: iso
Subtree mask:
Storage-type: nonVolatile
View Type: included
View status: active
View name: ViewDefault
MIB Subtree: snmpUsmMIB
Subtree mask:
Storage-type: nonVolatile
View Type: excluded
View status: active
View name: ViewDefault
MIB Subtree: snmpVacmMIB
Subtree mask:
Storage-type: nonVolatile
View Type: excluded
View status: active
View name: ViewDefault
MIB Subtree: snmpModules.18
Subtree mask:
Storage-type: nonVolatile
View Type: excluded
View
status: active
解决方法:
重新添加设备默认的mib view即可