无
无
模块型号:100G_BASE_ER4L_QSFP28 100G_BASE_LR4_QSFP28
问题描述:
现场使用我司100G光模块,反馈查看收发光时,短距10KM比长距40KM的发光强,我看收发光都在正常范围。
<H3C>DIS transceiver interface HundredGigE 3/0/10
HundredGigE3/0/10 transceiver information:
Transceiver Type : 100G_BASE_ER4L_QSFP28
Connector Type : LC
Wavelength(nm) : 1300
Transfer Distance(km) : 30(SMF)
Digital Diagnostic Monitoring : YES
Vendor Name : H3C
< H3C >DIS transceiver interface HundredGigE 3/0/11
HundredGigE3/0/11 transceiver information:
Transceiver Type : 100G_BASE_LR4_QSFP28
Connector Type : LC
Wavelength(nm) : 1300
Transfer Distance(km) : 10(SMF)
Digital Diagnostic Monitoring : YES
Vendor Name : H3C
Ordering Name : QSFP-100G-LR4-WDM1300
< H3C >dis transceiver diagnosis interface HundredGigE 3/0/10
HundredGigE3/0/10 transceiver diagnostic information:
Current diagnostic parameters:
[module] Temp.(°C) Voltage(V)
49 3.27
[channel] Bias(mA) RX power(dBm) TX power(dBm)
1 51.12 -7.41 1.09
2 60.49 -7.82 0.23
3 51.41 -7.47 1.17
4 59.59 -7.61 0.24
Alarm thresholds:
Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 75 3.63 110.00 -2.50 6.50
Low -5 2.97 20.00 -21.49 -2.50
< H3C >dis transceiver diagnosis interface HundredGigE 3/0/11
HundredGigE3/0/11 transceiver diagnostic information:
Current diagnostic parameters:
[module] Temp.(°C) Voltage(V)
45 3.29
[channel] Bias(mA) RX power(dBm) TX power(dBm)
1 40.83 2.37 2.84
2 39.44 2.49 2.48
3 39.23 2.24 3.14
4 37.62 1.79 3.03
Alarm thresholds:
Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 75 3.63 55.00 5.50 7.50
Low -5 2.97 25.00 -9.60 -8.30
经确认,为正常现象。
1、
2、
不涉及,为正常现象。