现场在9月7日进行网络切换测试时,对APP-DS和HLW-SW这两组S6520X堆叠环境进行重启切换后出现堆叠口不up问题,后于11月20日凌晨,对XX-B05-N05-OMS-ASW-6520这一组操作尝试复现,重启备设备后复现了堆叠口不up问题。
以11月20日复现的故障现象进行分析,该组设备以49和50口进行堆叠,重启备板slot2后,50口出现不UP问题。
1、
===============display irf link===============
Member 1
IRF Port Interface Status
1 disable --
2 FortyGigE1/0/49 UP
FortyGigE1/0/50 DOWN
Member 2
IRF Port Interface Status
1 FortyGigE2/0/49 UP
FortyGigE2/0/50 DOWN
2 disable --
=========================================================
2、
===============phy info 1 xq===============
port addr name ena[i/e] link[i/e] speed[i/e] du[i/e] an STP itf[i/e]
hg1 (20) - - ena/ - up/ - 40000/ - FD/- N/- FWD CR4/ -
hg2 (16) - - ena/ - down/ - 40000/ - FD/- N/- FWD CR4/ -
============================================================
===============phy info 2 xq===============
port addr name ena[i/e] link[i/e] speed[i/e] du[i/e] an STP itf[i/e]
hg1 (20) - - ena/ - up/ - 40000/ - FD/- N/- FWD CR4/ -
hg2 (16) - - ena/ - down/ - 40000/ - FD/- N/- FWD CR4/ -
3、
[XX-B05-N05-OMS-ASW-6520-probe]serdes read 1 0 50 0 //未重启侧的serdes信息。
… …
*******************************************************
***********Port Parameter********uiPhyPortNo[16]********
SignalDetect FALSE
AutoNegEnable TRUE
AutoNegBypassEnable TRUE
apEnable TRUE
ForceLinkDown NOT SUPPORT
ForcePeerDown FALSE
ForceLinkPass FALSE
SerdesTX TRUE
FecStatus(0-FEC/1-Disable/2-RS-FEC) 1
RemFault NOT SUPPORT
LocFault NOT SUPPORT
invertTx TRUE, invertRx TRUE
[XX-B05-N05-OMS-ASW-6520-probe]serdes read 2 0 50 0 //重启侧的serdes信息
... …
***********Port Parameter********uiPhyPortNo[16]********
SignalDetect TRUE
AutoNegEnable TRUE
AutoNegBypassEnable TRUE
apEnable TRUE
ForceLinkDown NOT SUPPORT
ForcePeerDown FALSE
ForceLinkPass FALSE
SerdesTX FALSE
FecStatus(0-FEC/1-Disable/2-RS-FEC) 0
RemFault NOT SUPPORT
LocFault NOT SUPPORT
invertTx TRUE, invertRx TRUE
[XX-B05-N05-OMS-ASW-6520-probe]
4、
input:10 1 3 cpssDxChPortApDebugInfoGet 1 16 /2/0/50侧AP协商信息
Addr :0x70e78e90
Port Control Realtime Log
=========================
Num of log entries 415
Current entry index 1418
04739060: AP SM Port 16, status 5 Tx Disable Success, O2(Tx Disable) 04739066: AP SM Port 16, status 6 Resolution In Progress, O3(Resolution) 04743860: AP SM Port 16, status 11 AP Resolution Timer Failure, O3(Resolution) 04743862: AP SM Port 16, status 11 AP Resolution Timer Failure, O1(Init) 04743869: AP SM Port 16, status 2 Init Success, O1(Init) 04743871: AP SM Port 16, status 3 Tx Disable In Progress, O2(Tx Disable) 04743931: AP SM Port 16, status 5 Tx Disable Success, O2(Tx Disable) 04743931: AP SM Port 16, status 5 Tx Disable Success, O2(Tx Disable) 04743937: AP SM Port 16, status 6 Resolution In Progress, O3(Resolution) 04748731: AP SM Port 16, status 11 AP Resolution Timer Failure, O3(Resolution) 04748733: AP SM Port 16, status 11 AP Resolution Timer Failure, O1(Init) 04748758: AP SM Port 16, status 2 Init Success, O1(Init) 04748760: AP SM Port 16, status 3 Tx Disable In Progress, O2(Tx Disable) 04748820: AP SM
return value is: 00000000
10 1 3 cpssDxChPortApDebugInfoGet 0 16 //1/0/50侧协商异常信息。
Addr :0x70e78e90
Port Control Realtime Log
=========================
Num of log entries 004
Current entry index 179
-258261135: Super Port 16, AP, AP Status Msg Sent to execute, O2(Low Pri Msg)
-258261133: Super Port 16, AP, AP Cfg Get Msg Sent to execute, O2(Low Pri Msg)
return value is: 00000000
5、
[XX-B05-N05-OMS-ASW-6520-FortyGigE1/0/50]dis this
#
interface FortyGigE1/0/50
description Link-irf-to-XX-B05-N05-OMS-ASW-6520-02:FG2/0/50
shutdown
#
return
[XX-B05-N05-OMS-ASW-6520-FortyGigE1/0/50]undo shut
[XX-B05-N05-OMS-ASW-6520-FortyGigE1/0/50]
[XX-B05-N05-OMS-ASW-6520-FortyGigE1/0/50]pro
[XX-B05-N05-OMS-ASW-6520-probe]phy info 1 xq
port addr name ena[i/e] link[i/e] speed[i/e] du[i/e] an STP itf[i/e]
hg1 (20) - - ena/ - up/ - 40000/ - FD/- N/- FWD CR4/ -
hg2 (16) - - ena/ - up/ - 40000/ - FD/- N/- FWD CR4/ -
[XX-B05-N05-OMS-ASW-6520-probe]phy info 2 xq
port addr name ena[i/e] link[i/e] speed[i/e] du[i/e] an STP itf[i/e]
hg1 (20) - - ena/ - up/ - 40000/ - FD/- N/- FWD CR4/ -
hg2 (16) - - ena/ - up/ - 40000/ - FD/- N/- FWD CR4/ -
[XX-B05-N05-OMS-ASW-6520-probe]
6、
[XX-B05-N05-OMS-ASW-6520-probe]phy info 1 xq //slot2重启后,1/0/49协商异常,无法up
port addr name ena[i/e] link[i/e] speed[i/e] du[i/e] an STP itf[i/e]
hg1 (20) - - ena/ - down/ - 40000/ - FD/- N/- FWD CR4/ -
hg2 (16) - - ena/ - up/ - 40000/ - FD/- N/- FWD CR4/ -
[XX-B05-N05-OMS-ASW-6520-probe]phy info 2 xq
port addr name ena[i/e] link[i/e] speed[i/e] du[i/e] an STP itf[i/e]
hg1 (20) - - ena/ - down/ - 40000/ - FD/- N/- FWD CR4/ -
hg2 (16) - - ena/ - up/ - 40000/ - FD/- N/- FWD CR4/ -
[XX-B05-N05-OMS-ASW-6520-probe]
XX-B05-N05-OMS-ASW-6520-probe]serdes read 1 0 49 0
... ...
***********Port Parameter********uiPhyPortNo[20]********
SignalDetect FALSE //异常侧signalDetect为FALSE,与现场一致。
AutoNegEnable TRUE
AutoNegBypassEnable TRUE
apEnable TRUE
ForceLinkDown NOT SUPPORT
ForcePeerDown FALSE
ForceLinkPass FALSE
SerdesTX TRUE
FecStatus(0-FEC/1-Disable/2-RS-FEC) 1
RemFault NOT SUPPORT
LocFault NOT SUPPORT
invertTx TRUE, invertRx TRUE
[XX-B05-N05-OMS-ASW-6520-probe]serdes read 2 0 49 0
... ...
***********Port Parameter********uiPhyPortNo[20]********
SignalDetect TRUE //重启侧signalDetect为TURE,与现场一致。
AutoNegEnable TRUE
AutoNegBypassEnable TRUE
apEnable TRUE
ForceLinkDown NOT SUPPORT
ForcePeerDown FALSE
ForceLinkPass FALSE
SerdesTX FALSE
FecStatus(0-FEC/1-Disable/2-RS-FEC) 0
RemFault NOT SUPPORT
LocFault NOT SUPPORT
invertTx TRUE, invertRx TRUE
[XX-B05-N05-OMS-ASW-6520-probe]
通过以上问题分析可以确认:
1、S6520X设备使用40G电缆进行AP协商时,因AP状态机迁移异常导致堆叠口无法UP,后续将通过软件版本修复。
2、40G光模块UP走的是RxTraing训练方式,不走AP协商流程,可临时选择使用40G光模块规避问题。
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作