设备有资源不足的日志提示
16:17:12:845 2023 S7003E-IRF RESMON/5/RESMON_MINOR_RECOVERY: -Chassis=1-Slot=1; -Resource=output_flowrate_22-Total=1000-Used=791-Free=209; Free resource increased above minor threshold 20%.
%@4820%Mar 2 16:17:12:859 2023 S7003E-IRF RESMON/5/RESMON_MINOR_RECOVERY: -Chassis=1-Slot=1; -Resource=output_flowrate_0-Total=1000-Used=791-Free=209; Free resource increased above minor threshold 20%.
%@4821%Mar 2 16:17:26:748 2023 S7003E-IRF RESMON/5/RESMON_MINOR_RECOVERY: -Chassis=2-Slot=1; -Resource=output_flowrate_0-Total=1000-Used=742-Free=258; Free resource increased above minor threshold 20%.
%@4822%Mar 2 17:12:28:405 2023 S7003E-IRF RESMON/4/RESMON_MINOR: -Chassis=2-Slot=1; -Resource=output_flowrate_2-Total=1000-Used=827-Free=173; Free resource decreased to or below minor threshold 20%.
%@4823%Mar 2 17:12:28:427 2023 S7003E-IRF RESMON/4/RESMON_MINOR: -Chassis=2-Slot=1; -Resource=output_flowrate_0-Total=1000-Used=831-Free=169; Free resource decreased to or below minor threshold 20%.
%@4824%Mar 2 17:12:44:530 2023 S7003E-IRF RESMON/4/RESMON_MINOR: -Chassis=1-Slot=1; -Resource=output_flowrate_22-Total=1000-Used=881-Free=119; Free resource decreased to or below minor threshold 20%.
查看日志手册有如下显示:
这个告警为 端口出方向使用速率的告警:
%@4824%Mar 2
17:12:44:530 2023 S7003E-IRF RESMON/4/RESMON_MINOR: -Chassis=1-Slot=1;
-Resource=output_flowrate_22-Total=1000-Used=881-Free=119; Free resource
decreased to or below minor threshold 20%.
日志中的数字是逻辑端口号:
====display
hardware internal port mapping chassis 1 slot 1====
GigabitEthernet1/1/0/23
0
34
22
0x122
0x77
1 up
可以在日志告警的时候多次收集如下命令:
先在源端口和目的端口的端口下,flow-interval 5改成5秒来观察
目的端口多次查看,看故障的时候出方向的队列长度变化:
display qos queue-statistics interface GigabitEthernet xxx outbound
查看一下源目端口的流量:
display
counters rate outbound interface xxx
看下是否都是正常流量,是否有异常。
如果都是正常流量,不想打印对应日志,可以通过undo
resource-monitor output syslog 命令关闭资源管理log日志,但是这样其他资源告警也不会显示在日志:
1.1.56 resource-monitor
output
resource-monitor
output命令用来配置资源告警通知的输出方向。
undo
resource-monitor output命令用来关闭资源告警通知的输出方向。
【命令】
resource-monitor
output { netconf-event | snmp-notification | syslog } *
undo
resource-monitor output [ netconf-event | snmp-notification | syslog ]*
或者调整资源告警门限值为0:
1.1.24 info-center logfile
alarm-threshold
info-center
logfile alarm-threshold命令用来配置单个日志文件使用率的告警门限。
undo
info-center logfile alarm-threshold命令用来恢复缺省情况。
【命令
info-center
logfile alarm-threshold usage
undo
info-center logfile alarm-threshold
查出异常流量,优化流量或关闭提示
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作