一台7500E插入此型号板卡LSQM1GP24TSC0
无告警
设备运行中发现接口17-24因 ADM down掉了,进行undo
shut的操作就会出现 25-32的接口被 ADM down,反之也是有影响
[H3C-if-range]dis int brief
GE3/0/17 UP 1G(a) F(a) T 1
GE3/0/18 DOWN auto A T 1
GE3/0/19 UP 1G(a) F(a) T 1
GE3/0/20 DOWN auto A T 1
GE3/0/21 UP 1G(a) F(a) T 1
GE3/0/22 DOWN auto A T 1
GE3/0/23 DOWN auto A T 1
GE3/0/24 DOWN auto A T 1
GE3/0/25 ADM auto A A 124
GE3/0/26 ADM auto A A 124
GE3/0/27 ADM auto A A 124
GE3/0/28 ADM auto A A 5
GE3/0/29 ADM auto A A 141
GE3/0/30 ADM auto A A 141
GE3/0/31 ADM auto A A 124
GE3/0/32 ADM auto A A 5
[H3C]interface range GigabitEthernet 3/0/22 to GigabitEthernet 3/0/27
[H3C-if-range]undo shutdown
[H3C-if-range]dis int brief
GE3/0/17 ADM auto A T 1 link-4haolou-2lou
GE3/0/18 ADM auto A T 1
GE3/0/19 ADM auto A T 1
GE3/0/20 ADM auto A T 1
GE3/0/21 ADM auto A T 1
GE3/0/22 ADM auto A T 1
GE3/0/23 ADM auto A T 1
GE3/0/24 ADM auto A T 1
GE3/0/25 UP 1G(a) F(a) A 124
GE3/0/26 UP 100M(a) F(a) A 124
GE3/0/27 UP 100M(a) F(a) A 124
GE3/0/28 UP 100M(a) F(a) A 5
GE3/0/29 DOWN auto A A 141
GE3/0/30 UP 1G(a) F(a) A 141
GE3/0/31 DOWN auto A A 124
GE3/0/32 UP 1G(a) F(a) A 5
官网查找此板卡的信息
此型号LSQM1GP24TSC0的板卡的接口属于combo口和SFP口不能同时使用,官网有说明
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作