22:19分2槽位板卡出现fault,导致所有ospf邻居中断,22:23后切回normal,公安传输义蓬站17槽视频监控业务以太网接口信号丢失,告警四分钟后自动恢复
22:19:34 2槽位LSQM1TGS16GPSA0自动重启,同时ospf震荡。
%@33081381%Sep 23 22:19:34:788 2023 SPJK-YP.HuiJu-S7506e DEV/2/BOARD_STATE_FAULT: Board state changed to Fault on slot 2, type is LSQM1TGS16GPSA0.
%@33081382%Sep 23 22:19:34:929 2023 SPJK-YP.HuiJu-S7506e OSPF/6/OSPF_LAST_NBR_DOWN: OSPF 1 Last neighbor down event: Router ID: 33.84.15.1 Local address: 33.84.15.84 Remote address: 33.84.15.65 Reason: Ospf_ifachange.
%@33081383%Sep 23 22:19:34:929 2023 SPJK-YP.HuiJu-S7506e OSPF/5/OSPF_NBR_CHG: OSPF 1 Neighbor 33.84.15.65(Vlan-interface200) changed from 2-WAY to DOWN.
%@33081384%Sep 23 22:19:34:930 2023 SPJK-YP.HuiJu-S7506e OSPF/5/OSPF_NBR_CHG: OSPF 1 Neighbor 33.84.15.66(Vlan-interface200) changed from 2-WAY to DOWN.
查看诊断信息,单板是控制通道检测失败重启。
--------------------Executed action records:--------------------
Slot 2:
1. 2023-09-23, 22:19:34 hot-rebooted by CONTROLPATH.
reason:CTRL_PATH. chip 255: the action executed 1 times.
Diagfile中也显示 控制通道检测失败,
%@87919^Sep 23 22:19:34:292 2023 SPJK-YP.HuiJu-S7506e DRVPLAT/3/DrvDebug:
LINE:1024
MOD:GOLD,TASK:PCHK,-FILE id 0x400001,SLOT:0--:
Control path check fail will reboot slot 2.
%@87920^Sep 23 22:19:34:769 2023 SPJK-YP.HuiJu-S7506e DRVPLAT/3/DrvDebug:
LINE:4179
MOD:DIAGAI,TASK:PCHK,-FILE id 0x470006,SLOT:0--:
Hot Reboot Finished, Slot:2
单板硬件故障,比如CPU等,建议更换单板解决。