【MVS】F5配置HA报错“01070661:3: Attempt to enable both Failover.ForceActive and Failover.ForceStandby.”
This is the result of a known issue. In BIG-IP version 10.1.0 and later, changes to the Redundancy State Preference setting on the High Availability > Redundancy screen may fail, and an error message similar to the following example will display in the Configuration utility:
01070661:3: Attempt to enable both Failover.ForceActive and Failover.ForceStandby.
This condition is only known to occur if the Active and Standby members of a high-availability pair previously had their redundancy state preferences changed from None to Active or Standby. Once the devices have had their settings set to prefer a specific role, an attempt to change the Redundancy State Preference from Active to Standby may result in the error condition and error message described previously.
F5 Product Development is tracking this issue as ID 252045 (formerly CR48012).
Note: This issue does not affect BIG-IP version 11.x and later.
Workaround
You can work around this issue by clearing and resetting the Redundancy State Preference setting. To do so, perform one of the following two procedures:
Clearing and Resetting the Redundancy State Preference setting from the Configuration utility