设备型号及版本:S12508F-AF R1152
现场之前BAGG52正常下发vlan mapping,后面配置做了改动,接口下开启了qinq enable,后面再下发vlan mapping时就报错。
XG1/2/0/31提示资源不足,XG2/2/0/31可以正常下发。
客户昨天晚上调整的时候的报错信息:
接口配置如下:
#
interface Ten-GigabitEthernet1/2/0/31
port link-mode bridge
description To 1227I-C_GSSZ-G0/2 10.28.0.3
port link-type hybrid
undo port hybrid vlan 1
port hybrid vlan 3 to 100 701 to 801 803 to 893 896 to 901 904 to 967 969 to 2000 2012 to 2811 2813 to 3100 3501 to 3913 3915 to 4093 tagged
port hybrid vlan 3914 untagged
qinq enable
shutdown
port link-aggregation group 52
#
#
interface Ten-GigabitEthernet2/2/0/31
port link-mode bridge
description 1227I-C_GSSZ-T2/0/25 10.28.0.3
port link-type hybrid
undo port hybrid vlan 1
port hybrid vlan 3 to 100 701 to 801 803 to 893 896 to 901 904 to 967 969 to 2000 2012 to 2811 2813 to 3100 3501 to 3913 3915 to 4093 tagged
port hybrid vlan 3914 untagged
qinq enable
vlan mapping nest range 101 to 700 3101 to 3500 nested-vlan 3914
port link-aggregation group 52
#
通过查看资源发现:
Interfaces: XGE2/2/0/25 to XGE2/2/0/48
---------------------------------------------------------------------
Type Total Reserved Configured Remaining Usage
---------------------------------------------------------------------
IFP ACL 16896 4096 12316 484 97%
IFP Meter 30720 79 10 30631 0%
IFP Counter 8191 80 10 8101 1%
EFP ACL 2176 0 1661 515 76%
Interfaces: XGE1/2/0/25 to XGE1/2/0/48
---------------------------------------------------------------------
Type Total Reserved Configured Remaining Usage
---------------------------------------------------------------------
IFP ACL 12800 4096 48 8656 32%
IFP Meter 30720 78 10 30632 0%
IFP Counter 8191 79 10 8102 1%
EFP ACL 6272 0 3322 2950 52%
经确认:使能QINQ会消耗系统acl资源:这个会消耗acl资源ifp方向,端口每个通过的vlan都会下发单独的acl匹配项。所以通过的vlan越多,acl资源消耗越多。这里的vlan是指端口permit的vlan。配置qinq enable命令会消耗更多的系统资源,建议仅在必要时进行配置。
该问题可以删除qinq再下发vlan mapping ,同时注意下接口放通的vlan是否都是必须的,如果非必要,可以精简一下。
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作