客户反馈Exaata x8-2 某一节点iLO重置,
“Power : Reset : major : /SP has been reset by: IPMI,”
查 MOS Exadata Storage Cells and DB Nodes reset ILOM periodically (Doc ID 2099390.1),ILOM模块会定期90天重启。
结合告警里面的关键信息,Power : Reset : major : /SP has been reset by: IPMI,,即IPMI发出的RESET指令,结合MOS文档说明,此告警解除,可以忽略。
详细信息如下:
Applies to:
Exadata X4-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata X5-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata X6-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
A user may notice that the ILOM of an Exadata's Storage Cells and DB Nodes will be reset occasionally.
When this happens the following entry in the system event list may be seen-
89 Thu Jul 9 20:33:25 2015 Power Reset major /SP has been reset by: IPMI, Reason: Set PSU state
When the ILOM is reset you will notice that the network switch connected to the network management port will report a "Link Down" for the port while the reset is in progress.
Also of note is that the OS will log the disconnecting of the ILOM's virtual usb devices CD-ROM/floppy/etc.
Cause
Starting with Exadata release 11.2.3.3.0 each server has it's own periodic reset time which will perform a reset of the ILOM every 90 days.
In addition to these scheduled resets the MS process can also reset ILOM prior to the periodic target reset time if it times out when accessing the ILOM.
When this reset is initiated by the Exadata software the following entry will be seen in the ms-odl.log file
[2014-05-11T17:58:51.006+09:00] [ossmgmt] [NOTIFICATION] [] [common.hwadapter.bmcadp.BmcIpmiTool] [tid: 38] [ecid: nnn.nnn.nnn.nnn:75793:1399798731006:174860,0] Periodic reset interval is up. The ILOM will now be reset.
This change is documented in the what's new section of the Exadata overview document: ***.***/cd/E50790_01/doc/doc.121/e51953/app_whatsnew.htm#BGGDGCIE
Solution
This behavior is normal and expected. The Exadata system is configured so that a Server's ILOM is reset every 90 days.