组网及说明
HPE MR Gen11, Gen10 Plus, and Gen10 Storage Controllers - Rebuild Does Not Start Automatically After Replacing the Controllers
文档ID:a00156397en_us Last Updated: 2026-01-16
影响范围
HPE MR Gen10 Plus and Gen11 controllers
- HPE MR408i-o Gen11 x8 Lanes 4GB Cache OCP SPDM Storage Controller (P58335-B21)
- HPE MR416i-o Gen11 x16 Lanes 8GB Cache OCP SPDM Storage Controller (P47781-B21)
- HPE MR216i-o Gen11 x16 Lanes without Cache OCP SPDM Storage Controller (P47789-B21)
- HPE MR408i-p Gen11 x8 Lanes 4GB Cache PCI SPDM Plug-in Storage Controller (P74775-B21)
- HPE MR416i-p Gen11 x16 Lanes 8GB Cache PCI SPDM Plug-in Storage Controller (P47777-B21)
- HPE MR216i-p Gen11 x16 Lanes without Cache PCI SPDM Plug-in Storage Controller (P47785-B21)
- HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P26279-B21)
- HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P06367-B21)
- HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26325-B21)
- HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26324-B21)
HPE Smart Array MR Gen10 controllers
- HPE Smart Array P824i-p MR Gen10 12G SAS PCIe Controller
问题描述
更换 HPE MR Gen11、Gen10 Plus 及 Gen10 存储控制器(使用原有硬盘/固态硬盘组)后,若原控制器上的逻辑驱动器已处于降级状态,且有一个或多个硬盘已发生故障,则重建操作不会自动启动。
过程分析
解决方法
为避免此问题,HPE 建议仅在所有卷状态均为“最佳(optimal)”时才更换 MR 控制器。如果任何卷处于降级或重建状态,请勿更换控制器;
若已更换,需通过 HPE MR Storage Administrator (MRSA) 窗口右侧的“Elements Actions” 部分,在新控制器上手动启动阵列重建,以使卷恢复至optimal状态。
如需在新控制器上手动启动重建,请在 HPE MR Storage Administrator (MRSA) 窗口右侧的“Elements Actions”部分执行以下步骤,手动启动替换硬盘上的阵列重建。
1. 选择Drives > Unconfigured Good Drives ,选择待替换的硬盘,然后点击Assign Dedicated Spare.

2. 弹出对话框,选择要分配专用热备盘的降级阵列。

3. 替换的硬盘已更改为"Configured, status Rebuild."

一旦重建完成,该硬盘将显示为“在线”状态,而整个阵列也将显示为“最佳”状态。