组网及说明
HPE MR Gen10 Plus and Gen11 Storage Controllers - A "FW in FAULT State” is Observed in Linux Operating System Driver Logs After a Firmware Update
文档ID:a00159228en_us Last Updated: 2026-04-29
影响范围
HPE MR Gen10 Plus 和 Gen11 storage controllers:
- HPE MR408i-o Gen11 x8 Lanes 4GB Cache OCP SPDM Storage Controller (P58335-B21)
- HPE MR416i-o Gen11 x16 Lanes 8GB Cache OCP SPDM Storage Controller (P47781-B21)
- HPE MR216i-o Gen11 x16 Lanes without Cache OCP SPDM Storage Controller (P47789-B21)
- HPE MR408i-p Gen11 x8 Lanes 4GB Cache PCI SPDM Plug-in Storage Controller (P74775-B21)
- HPE MR416i-p Gen11 x16 Lanes 8GB Cache PCI SPDM Plug-in Storage Controller (P47777-B21)
- HPE MR216i-p Gen11 x16 Lanes without Cache PCI SPDM Plug-in Storage Controller (P47785-B21)
- HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P26279-B21)
- HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P06367-B21)
- HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26325-B21)
- HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26324-B21)
问题描述
对 HPE MR Gen10 Plus、Gen11 存储控制器进行在线固件刷新时,Linux 驱动日志中会出现 “FW in FAULT state” 日志提示。
所有受支持的 Linux 操作系统,在固件升级成功完成后均会出现该日志。

过程分析
解决方法
该日志信息不会造成阵列控制器任何功能丢失,主机及系统管理员无需执行任何修复操作。
可通过 iLO web中的IML日志查看并确认固件刷新的进度及完成状态。
示例:
Firmware flashed (Success: Device in slot 2: active fw [REDACTED], pending fw [N/A])
Firmware flashed (Firmware Package - HPE MR408i-p Gen11 Tri Mode Controller [REDACTED])
Linux 驱动日志中出现的 “FW in FAULT state(固件处于故障状态)” 提示,是在线固件升级过程中固件与主机驱动握手交互机制的正常现象,并不代表存在实际故障,也不会影响系统正常运行。
由于该日志会在多种场景下触发,且主机驱动无法仅凭此条日志区分是真实故障还是正常升级流程,因此无法单独屏蔽该提示信息。
本次固件升级可正常完成,无需重启服务器,也无需采取任何修复处理措施。