两台S6900-54QF-F配置三层动态聚合,并配置三层聚合子接口配置IP(端口UP) ,但直连无法互ping成功(聚合口IP可以ping通,聚合子接口IP无法互通),无相关ARP表项等。
配置如下:
设备1
interface Route-Aggregation51
ip address 200.1.1.2 255.255.255.252
link-aggregation mode dynamic
#
interface Route-Aggregation51.3992
ip address 10.191.101.170 255.255.255.252
设备2
interface Route-Aggregation51
ip address 200.1.1.1 255.255.255.252
link-aggregation mode dynamic
#
interface Route-Aggregation51.3992
ip address 10.191.101.169 255.255.255.252
相关三层汇聚子接口无法正常学习到ARP 表项信息。
路由聚合子接口对应的VLAN表的 VLAN_CLASS_ID 被清零了,导致ARP请求无法上送CPU。
[6900-54QT-probe]bcm s 2 c 0 d/chg/vlan/1
VLAN.ipipe0[1]: <VLAN_PROFILE_PTR=1,VLAN_CLASS_ID=2,VALID=1,STG=1,PORT_BITMAP=0x
0000000000022021ffffffffffff,ING_PORT_BITMAP=0x0000000000022021ffffffffffff,FID_
ID=1,EVEN_PARITY_1=1,>
Acl-Type RX IPv4 High, Stage IFP, Pipe 0, Global, Installed, Active
Prio Mjr/Sub 523/27, Group 16 [16], Slice/Idx 10/4, Entry 25, Double: 3588/3844
Rule Match --------
Ports:
0x0000000000000000000000000000000000000000000001fffffffffffffff
ffe
0x0000000000000000000000000000000000000200000001fffffffffffffff
fff
Lookup: VLAN ID valid[y], STP forwarding, 0x1c, 0x1c
Dest mac: FFFF-FFFF-FFFF, FFFF-FFFF-FFFF
EtherType: 0x806, 0xffff
SysmRule Index : 29
Vlan Class id: 0x2 Mask: 0x2
前该设备子,直接删除三层汇聚子接口重新建立即可刷新表项,规避该问题。
目前该设备子接口编号和vlan接口相同时,共用vlan。删除一个,vlan class id就会被清掉。用户现场先是建立了VLAN 接口3992 和三层汇聚子接口51.3992,后续删除了3992 的VLAN虚接口,导致vlan class id 被清零,ARP学习出现异常。
后续操作中最好避免类似操作,或者将两者均删除重建。