AR-SR8808-1 (pe)等价路由双归属到上行pe,到目的网络是等价路由。出接口分别是ten8/0/1和ten7/0/1。但是看出接口流量,却严重负载不均,流量一个接口为30%,另一个只有6%。
[YiAnHuaYuan-AR-SR8808-1]dis int te 8/0/1
Last 300 seconds input: 125180 packets/sec 73977330 bytes/sec 6%
Last 300 seconds output: 272360 packets/sec 365427800 bytes/sec 30%
Peak value of input: 259302010 bytes/sec, at 2014-12-29 14:41:38
Peak value of output: 1206910900 bytes/sec, at 2015-01-03 21:47:52
[YiAnHuaYuan-AR-SR8808-1]dis int te 7/0/1
Last 300 seconds input: 84110 packets/sec 93941220 bytes/sec 8%
Last 300 seconds output: 79670 packets/sec 73838730 bytes/sec 6%
Peak value of input: 380783280 bytes/sec, at 2014-12-29 17:51:52
1.SR88作为PE双上行的组网,若希望实现双上行ECMP负载分担,需要同步开启隧道策略,调整LSP负载分担数目,才能实现负载分担。默认情况下 SR88未使能MPLS LSP等价,如果存在多条LSP,则优选先建立的LSP,但可通过配置tunnel-policy来实现LSP的等价。
[H3C]tunnel-policy 1
[H3C-tunnel-policy-1]tunnel select-seq lsp load-balance-number 2
[H3C]ip vpn-instance 1
[H3C-vpn-instance-1]tnl-policy 1
2.SR8800只在SPE模式下支持LSP等价,负载分担方式为逐流,最大支持8条负载分担的隧道条数;在SPC、Hybrid模式下不支持,现场为SPC板和SPE板混插,设备只能工作还Hybrid模式,tunnel-policy里负载分担的个数只能为一:
[SR8800(2108)]display system working mode
Current system working mode : Hybrid
Working mode after system restart: Hybrid
[SR8800(2108)-tunnel-policy-1]tunnel select-seq lsp load-balance-number ?
INTEGER<1-1> Tunnel load balance number
3.此问题为芯片限制,不能通过软件修改。因此建议现场扩充链路,或者更改SPC板为SPE板,并修改工作模式为SPE模式规避。
更改SPC板为SPE板,并修改工作模式为SPE模式规避。并配置隧道数目为2。
[SR8800(2108)-tunnel-policy-1]tunnel select-seq lsp load-balance-number 2
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作