问题描述:
路由器上配置哑终端屏幕切换。配置2屏或3屏切换正常,但配置4屏时,哑终端屏幕无切屏菜单回显,处于黑屏状态。但此时根据路由器侧配置选择业务对应的选项,仍可进入相应业务。
关键配置:
tty-app sender connection 0 10.xxx.xxx.22 9001 1 YouZhengChuXu
tty-app sender connection 1 10.xxx.xxx.22 9002 1 ZhongJianYeWu
tty-app sender connection 2 10.xxx.xxx.22 9004 1 wen-test
tty-app sender connection 3 10.xxx.xxx.22 9003 1 KaiFangJiJin
tty-app sender connection 4 10.xxx.xxx.22 9004 1 wen-test
tty-app sender connection 5 10.xxx.xxx.22 9002 1 ZhongJianYeWu
tty-app sender connection 6 10.xxx.xxx.5 8001 1 DianZhiHuiDui
tty-app sender connection 7 10.xxx.xxx.22 9003 1 KaiFangJiJin
tty-app sender connection 8 10.xxx.xxx.10 9001 1 BaoKanFaXing
firewall enable
!
interface Async1
physical-mode async
undo modem
undo detect DSR-DTR
baudrate 57600
async mode tty 1 0 4
async mode tty 1 1 5
async mode tty 1 2 6
async mode tty 1 3 7
tty menu-key 20
tty redraw-key 24
tty test-key 2
flow-control none
link-protocol ppp
!
interface Async2
physical-mode async
undo modem
undo detect DSR-DTR
baudrate 57600
async mode tty 6 0 8
flow-control none
link-protocol ppp
!采取措施:
将tty-app命令中的app-name的字符数减少后,4屏菜单能在终端上正常回显。