现场两台S12510X-AF交换机准备做irf堆叠,但在堆叠的过程中,现场发现两台交换机始终无法堆叠成功;
现场操作人员反馈堆叠步骤都是按配置指导进行,且现场设备的软件版本、ecmp规格等都是相同的,同时也核对过配置指导手册中的堆叠限制,都是符合的,但是堆叠就是无法完成,即两台交换机做好配置后激活IRF端口配置,连线,堆叠却不发生,备设备不重启;
1、 查看两台交换机的log日志,发现其中一台交换机,框2交换机,存在irf堆叠设备TGNum配置需一致的提示,即现网两框设备的TGNum配置不一致,故而导致了堆叠无法进行,具体日志信息见下:
%Oct 20 15:13:18:163 2016 H3C IFNET/3/PHY_UPDOWN: FortyGigE2/5/0/5 link status is up.
%Oct 20 15:13:18:163 2016 H3C IFNET/5/LINK_UPDOWN: Line protocol on the interface FortyGigE2/5/0/5 is up.
%Oct 20 15:13:18:238 2016 H3C IFNET/3/PHY_UPDOWN: FortyGigE2/2/0/5 link status is up.
%Oct 20 15:13:18:239 2016 H3C IFNET/5/LINK_UPDOWN: Line protocol on the interface FortyGigE2/2/0/5 is up.
%Oct 20 15:13:18:340 2016 H3C STM/6/STM_LINK_STATUS_UP: IRF port 1 is up.
%Oct 20 15:13:18:511 2016 H3C IFNET/3/PHY_UPDOWN: FortyGigE2/3/0/5 link status is up.
%Oct 20 15:13:18:511 2016 H3C IFNET/5/LINK_UPDOWN: Line protocol on the interface FortyGigE2/3/0/5 is up.
%Oct 20 15:13:18:625 2016 H3C IFNET/3/PHY_UPDOWN: FortyGigE2/4/0/5 link status is up.
%Oct 20 15:13:18:626 2016 H3C IFNET/5/LINK_UPDOWN: Line protocol on the interface FortyGigE2/4/0/5 is up.
%Oct 20 15:13:20:652 2016 H3C DRVPLAT/4/DrvDebug:
The TGNum configuration should be the same on devices in one IRF. Please check it on the neighbor device connected to IRF-port 1
%Oct 20 15:13:20:652 2016 H3C STM/3/STM_SOMER_CHECK: Neighbor of IRF port 1 can't be stacked.
%Oct 20 15:13:20:861 2016 H3C STM/3/STM_LINK_STATUS_DOWN: IRF port 1 is down.
2、 TGNum的含义是交换机聚合规格,即现网两框设备的聚合规格不一致,故而导致了堆叠失败;让现场通过display link-aggregation capability命令查看两台交换机的聚合规格,发现两台设备的聚合规格确实不一样,一台为1024*16,另外一台为512*32;
Default link aggregation capability:
Maximum groups: 1024
Maximum Selected ports per group: 16
Current link aggregation capability:
Maximum groups: 1024
Maximum Selected ports per group: 16
Link aggregation capability at the next reboot:
Maximum groups: 1024
Maximum Selected ports per group: 16
Supported link aggregation capability list:
1024*16 512*32 256*64
表1-1 display link-aggregation capability命令显示信息描述表
字段 |
描述 |
Default link aggregation capability |
缺省情况下,设备支持的聚合能力 |
Current link aggregation capability |
设备当前生效的聚合能力 |
Link aggregation capability at the next reboot |
下一次启动时生效的聚合能力 |
Maximum groups: 1024 |
设备支持创建的最大聚合组数 |
Maximum Selected ports per group: 16 |
每个聚合组中最大选中的端口数 |
Supported link aggregation capability list |
设备支持配置的聚合能力:支持创建的最大聚合组数*每个聚合组中最大选中端口数 |
现场通过link-aggregation capability max-group 1024 max-selected-port 16 命令,将两台设备的聚合规格修改成一样,即将框2的聚合规格修改为默认的1024*16,问题解决;
在实际的项目实施部署中,交换机堆叠失败的情况是很常见的,在设备无法进行堆叠的时候,有以下建议:
1、 查看配置指导中的“组建IRF时的注意事项”,确认是否存在注意事项中的情况,比如系统模式、ECMP规格需一致等;ECMP规格不一致导致IRF堆叠无法建立的案例较多,需注意;
2、 查看设备的log日志信息,从设备的日志中,可获取到较多有用的信息,比如ECMP规格不一致提示、TGNum聚合规格不一致等信息;
3、 检测堆叠物理接口所使用的光模块是否为我司出厂的正规模块等。