当低端交换机出现上电后系统无法正常进入命令行状态并反复重启或交换机在重启时提示Error的情况时,可通过测试交换机内存的方法确认是否存在硬件故障。在测试过程中,如果提示“ERROR”说明内存硬件故障,需要返修。
S3100-SI/EI系列交换机内存测试方法如下:
在系统启动时进入Bootrom菜单,按住“Ctrl+t”后回车,输入“Y”进入装备视图,输入Test sdram后回车进行测试,完毕后使用reset命令重启设备。
BOOT MENU
1. Download application file to flash
2. Select application file to boot
3. Display all files in flash
4. Delete file from flash
5. Modify bootrom password
6. Enter bootrom upgrade menu
7. Skip current configuration file
8. Set bootrom password recovery
9. Set switch startup mode
0. Reboot
Enter your choice(0-9):
Are you sure to test your equipment? Yes or No(Y/N) y
Enter board test environment...
password: *********** //密码为huawei-3com
Enter board test, press 'help' for help
TEST>Test sdram
Testing SDRAM...................................................................
..................................................done!
@
Sdram Selftest OK!
$$
TEST>reset
System rebooting...
Starting......
S5100-SI/EI、S3600-SI/EI、S5600和S5500-SI/EI系列交换机内存测试方法同S3100-SI/EI系列交换机,密码亦相同。
S3610/5610系列交换机内存测试方法如下:
(1)当前交换机bootrom版本为145及之前:操作方法与S3100-SI/EI系列交换机相同,但测试命令不是Test sdram,而是如下两条命令。
test SDRAMDataAddr
test SDRAMUnit
(2)当前交换机bootrom版本为202至205时不支持内存测试命令。
(3)当前交换机bootrom版本为206及之后测试方法如下。
在系统启动时进入Bootrom菜单,按住“Ctrl+h”后回车进入装备视图。
BOOT MENU
1. Download application file to flash
2. Select application file to boot
3. Display all files in flash
4. Delete file from flash
5. Modify bootrom password
6. Enter bootrom upgrade menu
7. Skip current configuration file
8. Set bootrom password recovery
9. Set switch startup mode
0. Reboot
Enter your choice(0-9):
Please input password:****** //密码为H3C-OM
BootWare> mtestbus
CPU SDRAM DATA and ADDRESS line selftest OK!
BootWare> mtestunit
DRAM testing: from 0x00010000 to 0x0769d000
.........
CPU SDRAM Unit selftest OK!
BootWare> reset
System is starting…………
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作