使用Monitor-link功能监控上行接口,联动下行接口为聚合组。当上行接口down后,monitor-link功能执行动作将联动接口down。
需要确认monitor-link将聚合组置为down后,成员口处于什么状态。
经验证聚合口被monitor-link置down后,成员口也会被链路聚合模块关闭。
dis monitor-link group 1
Monitor link group 1 information:
Group status : UP
Downlink up-delay: 0(s)
Last-up-time : 09:32:58 2022/05/31
Last-down-time : -
Up-port-threshold: 1
Member Role Status
--------------------------------------------
GE5/1/15 UPLINK UP
RAGG2 DOWNLINK UP
Aggregate Interface: Route-Aggregation2
Aggregation Mode: Static
Loadsharing Type: Shar
Port Status Priority Oper-Key
GE5/1/13 S 32768 3
关闭uplink接口G5/1/15后,downlink接口均变成双down状态:
[GigabitEthernet5/1/15]shu
[GigabitEthernet5/1/15]dis int ragg 2
Route-Aggregation2
Current state: DOWN ( Monitor-Link uplink down )
Line protocol state: DOWN
Description: Route-Aggregation2 Interface
Maximum transmission unit: 1500
……
[SR88-DOWN-GigabitEthernet5/1/15]dis int ge 5/1/13
GigabitEthernet5/1/13
Current state: DOWN ( Link-Aggregation interface down )
Line protocol state: DOWN(LAGG)