S6805,R6635
现场设备2/0/22口插光转电模块,并接了一根网线,对端没有接任何设备,但是这个口突然震荡了一下
%Mar 18 19:33:37:820 2001 ZH_SRV-2-C_row-SW IFNET/3/PHY_UPDOWN: Physical state on the interface Ten-GigabitEthernet2/0/22 changed to up.
%Mar 18 19:33:37:828 2001 ZH_SRV-2-C_row-SW IFNET/5/LINK_UPDOWN: Line protocol state on the interface Ten-GigabitEthernet2/0/22 changed to up.
%Mar 18 19:33:41:302 2001 ZH_SRV-2-C_row-SW IFNET/3/PHY_UPDOWN: Physical state on the interface Ten-GigabitEthernet2/0/22 changed to down.
%Mar 18 19:33:41:324 2001 ZH_SRV-2-C_row-SW IFNET/5/LINK_UPDOWN: Line protocol state on the interface Ten-GigabitEthernet2/0/22 changed to down.
[99]: Line=1488 val[0]=8221 val[1]=0 val[2]=0 SdL[0]=0x0 SdL[1]=0x0 SdL[2]=0x0 Time=03/18/2001 19:33:41:726
linkinfo=0x201d:down.readphy.pma.pcs.xgs.
经过分析,发现该设备对于光转电模块轮询机制和端口recover功能在代码适配上有点bug,目前已经出补丁优化
·
·
·
可以通过R6635H09解决
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作