客户通过ssh登录设备的网管口,然后display
cu | inc stp的回显很久(其它的关键词也是),长达8到10秒钟,让ssh的client长ping设备大包无丢包现象
查询诊断,cpu和内存均占用不高,查看配置文件,配置总共有3595行,故用display current-configuration | include xxx命令行检索配置时,原理是通过正则表达式进行匹配,由于配置文件内容太多,故匹配时间较长,8s属于正常范围。
===============display current-cOnfiguration===============
interface Ten-GigabitEthernet1/1/0/22
port link-mode bridge
description To_A#09_SangFor_探针eth9
speed 1000
mirroring-group 1 monitor-port
===========================================================
===============display cpu===============
Chassis 1 Slot 0 CPU 0 CPU usage:
2% in last 5 seconds
1% in last 1 minute
1% in last 5 minutes
Chassis 1 Slot 1 CPU 0 CPU usage:
13% in last 5 seconds
14% in last 1 minute
14% in last 5 minutes
Chassis 1 Slot 2 CPU 0 CPU usage:
3% in last 5 seconds
3% in last 1 minute
3% in last 5 minutes
Chassis 1 Slot 3 CPU 0 CPU usage:
38% in last 5 seconds
6% in last 1 minute
5% in last 5 minutes
进一步对比分析:
多次输入dis cur | inc stp命令
1.堆叠模式:
ctc设备-7506XG:配置文件3365行,输出结果平均时间为8.6s左右
bcm设备-10508:配置文件4541行,输出结果平均时间为6.8s左右
2.非堆叠模式:
ctc设备-7506XG:配置文件3360行,输出结果平均时间为8.5s左右
bcm设备-10508:配置文件4534行,输出结果平均时间为6.6s左右
可以确认这台7506XG的主控板CPU是CTC自带的2核CPU,性能是要比其它独立设计的主控差一点。现场可以酌情更换LSCM3MPUS06A0这个主控,是独立的飞腾CPU,效果就会好一些。
可以确认这台7506XG的主控板CPU是CTC自带的2核CPU,性能是要比其它独立设计的主控差一点。现场可以酌情更换LSCM3MPUS06A0这个主控,是独立的飞腾CPU,效果就会好一些。