某局点使用HPE C3000刀箱加VC的配置如下:
互联模块1号位置:HPE Virtual Connect 10/10D
互联模块2号位置:8Gb/12c SAN Switch
VCM界面配置好后,VCM界面显示都正常而且网络也能通,但是只要bay2上安装了san switch后,网络依然可以通,但是VCM界面所有上联口都显示not linked。
VC show all日志中有如下记录Overall Domain Status : Critical : The domain is incapable of managing its
contained VC components.
Status Cause : 1 of 1 enclosures are abnormal (and not degraded) in the domain
Root Cause : Module is not supported next to module Brocade 8Gb/12c SAN Switch
in horizontal adjacent bay enc0:iobay2
各个server profile都提示The server profile is assigned to a server reported as unknown by the OA, or the server has lost communication with the OA.
HPE C3000刀箱在安装VC模块时的要求如下:
The use of an HP VC-Enet in bay 1 and a Fibre Channel module (for example, VC-FC, SNA
switch, or FC pass-thru) in bay 2 is not supported in c3000 enclosures.
意即VC模块水平相邻的位置必须要插VC模块,此时该水平相邻位置插其它类型设备是不支持的。
将HBA卡从服务器扩展1号槽位移到2号槽位,并将SAN switch移动到互联模块3号位置。
部署安装C3000刀箱并有VC模块存在的情况下,优先查询安装设置手册-“HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide”。
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作