文档ID:a00151227en_us Last Updated: 2025-10-07
影响范围
该问题首先在ProLiant ML110 Gen11上观察到。由于所有Gen11和Gen12平台使用相同的计算方法,因此这些平台也可能发生这种情况。
Hardware Platforms Affected:
HPE ProLiant RL300 Gen11, HPE ProLiant DL365 Gen11, HPE ProLiant
DL385 Gen11, HPE ProLiant DL325 Gen11, HPE ProLiant DL345 Gen11, HPE ProLiant
DL360 Gen11, HPE ProLiant DL380 Gen11, HPE ProLiant DL380a Gen11, HPE ProLiant
ML350 Gen11, HPE Synergy 480 Gen11 Compute Module, HPE ProLiant ML110 Gen11,
HPE ProLiant DL560 Gen11, HPE ProLiant DL110 Gen11 Telco, HPE ProLiant DL20
Gen11, HPE ProLiant ML30 Gen11, HPE ProLiant MicroServer Gen11, HPE ProLiant
DL384 Gen11, HPE ProLiant Compute DL320 Gen12, HPE ProLiant Compute DL340
Gen12, HPE ProLiant Compute DL384 Gen12, HPE ProLiant DL145 Gen11, HPE ProLiant
Compute DL380a Gen12, HPE ProLiant Compute DL360 Gen12, HPE ProLiant Compute
DL380 Gen12, HPE ProLiant Compute ML350 Gen12, HPE Synergy 480 Gen12 Compute
Module, HPE ProLiant Compute DL580 Gen12, HPE ProLiant Compute DL325 Gen12, HPE
ProLiant Compute DL345 Gen12
在HPE ProLiant ML110 Gen11服务器上,当通过系统配置(RBSU)手动更改时区设置保存重启后,设置将恢复到以前的值。在选择某些时区保存更改时,遇到此问题的服务器也会显示以下错误:
"Submit Fail For Form: BIOS/Platform Configuration (RBSU)"
N/A
当出现此问题时,通过manufacturer defaults可临时绕过此问题。
此问题将在未来BIOS 版本中得到纠正,这将优化时间设置。本文档将在获得更多信息时更新。